The use of calibration approaches for quantitative GC/MS analysis-secobarbital example

نویسندگان

  • Yi-Hung Wu
  • Wei-Tun Chang
  • Chin-Thin Wang
  • Yang-Hung Liang
چکیده

One-point, Linear, Hyperbolic and Polynomial calibration approaches were adopted to elucidate the quantitative effectiveness of standard solutions of 10 to 800 ng/mL secobarbital by comparing theoretical and observed concentrations. Different concentrations of internal standard(IS), 50 and 200 ng/mL, were added to standard solutions for comparison purpose. Two GC column temperature programs, a high ramp rate of 20 °C per minute and a low ramp rate of 2 °C per minute, were used to generate different degrees of peak-overlap and ion cross-contributions to evaluate the most appropriate application for each calibration approach. The ion cross-contribution deriving from IS to analyte leads to the significantly positive observed concentration at low concentration levels while using One-point calibration. This phenomenon is clearly exhibited by ion pairs containing the higher ion cross-contribution, the larger added IS magnitude, and the higher ramp rate of temperature programming. One-point calibration is appropriately used for the quantitation that concentrations of analytes are close to that of the calibrator. In addition to the ion cross contribution, the “non-proportional over-all change in ionization efficiency” phenomenon will also affect the effectiveness under Linear calibration. Thus, it can be adopted by using appropriate derivatization, IS and/or its magnitude, and temperature programming along with the suitable concentration range of standard solutions. The Hyperbolic calibration can be generally used for determining analytes at various concentration levels without interference from ion cross-contribution factor. The Polynomial approach can completely fit in ion-pair intensity ratios of standard solutions for each ion-pair yielding the ideal observed concentrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Isotopic analogues as internal standards for quantitative analyses of drugs and metabolites by GC-MS--nonlinear calibration approaches.

In order to achieve accurate quantitation of drugs and metabolites (analytes) in complex matrices, 2H- (and less commonly 13C-) labeled analogues of the analytes are now routinely adapted as the internal standards (IS) using linear calibration models to fit data generated by selected ion monitoring gas chromatography-mass spectrometry (GC-MS) protocols. In this study, the effects of cross-contr...

متن کامل

Detector response and intensity cross-contribution as contributing factors to the observed non-linear calibration curves in mass spectrometric analysis.

It is a common knowledge that detector fatigue causes a calibration curve to deviate from the preferred linear relationship at the higher concentration end. With the adaptation of an isotopically labeled analog of the analyte as the internal standard (IS), cross-contribution (CC) of the intensities monitored for the ions designating the analyte and the IS can also result in a non-linear relatio...

متن کامل

A Multi Residue GC-MS Method for Determination of 12 Pesticides in Cucumber

Cucumber is one of the main vegetables in Iranian food basket. A wide range of pesticides are used for crops protection during the cultivation of vegetables such as cucumber due to heavy pest infestation. Analysis of pesticide residues in food and other environmental commodities have become essential requirement for consumers, producers, and food quality control authorities. This study was aime...

متن کامل

A Multi Residue GC-MS Method for Determination of 12 Pesticides in Cucumber

Cucumber is one of the main vegetables in Iranian food basket. A wide range of pesticides are used for crops protection during the cultivation of vegetables such as cucumber due to heavy pest infestation. Analysis of pesticide residues in food and other environmental commodities have become essential requirement for consumers, producers, and food quality control authorities. This study was aime...

متن کامل

Spiked Calibration Curve: A Valid Method for Simultaneous Analysis of Pesticides in Melon Using Gas Chromatography Mass Spectrometry (GC/MS)

Recently, with increasing public awareness of food safety, developments of some valid and rapidly analytical methods are required for the determination of residual pesticides in crops.This study was conducted on validation of a reliable, accurate and precise method for multi analysis of pesticides residue in melon as a main fruit in Iranian food basket. A reliable, and valid method...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005