Similar effect of stem geometry on radiological changes with 2 types of cemented straight stem

نویسندگان

  • Martin Clauss
  • Lilianna Bolliger
  • Daniel Brandenberger
  • Peter E Ochsner
  • Thomas Ilchmann
چکیده

BACKGROUND AND PURPOSE There are 2 basic principles in cemented stem fixation: shape-closed and force-closed. We investigated 2 shape-closed straight stems, the Müller (MSS) and the Virtec (VSS), which differ only in geometrical cross section, to determine whether the difference in stem shape would affect the radiological results or long-term survival. PATIENTS AND METHODS We included 711 hips (in 646 patients) that were operated on between July 1996 and July 2003. Patients randomly received either an MSS (n = 356) or a VSS (n = 355) and were followed prospectively. Radiographs taken at a follow-up of > 10 years were analyzed for osteolysis. Kaplan-Meier (KM) survival analysis was performed using various endpoints. We also performed Cox regression analysis to identify risk factors for aseptic loosening and osteolysis of the stem. RESULTS After 10 years, KM survival with "revision of any component for any reason" was 92% (95% CI: 88-95) for the MSS and 95% (CI: 92-97) for the VSS (p = 0.1). With "revision for aseptic loosening of the stem" as the endpoint, KM survival was 96% (CI: 9-98) for the MSS and 98% (CI: 97-100) for the VSS (p = 0.2). Cox regression showed that none of the risk factors analyzed were independent regarding aseptic loosening of the stem or regarding osteolysis. INTERPRETATION The MSS and the VSS showed excellent survival for aseptic loosening after 10 years. For the 2 different stem designs, we did not find any independent risk factors for aseptic loosening or development of osteolysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term survival of a cemented titanium-aluminium-vanadium alloy straight-stem femoral component.

We present a retrospective series of 170 cemented titanium straight-stem femoral components combined with two types of femoral head: cobalt-chromium (CoCr) alloy (114 heads) and alumina ceramic (50 heads). Of the study group, 55 patients (55 stems) had died and six (six stems) were lost to follow-up. At a mean of 13.1 years (3 to 15.3) 26 stems had been revised for aseptic loosening. The mean f...

متن کامل

Prospective two-year subsidence analysis of 100 cemented polished straight stems - a short-term clinical and radiological observation

BACKGROUND Cemented stems show good long-term results and the survival of new implants can be predicted by their early subsidence. With EBRA-FCA (Femoral Component Analysis using Einzel-Bild-Röntgen-Analyse) early subsidence as an early indicator for later aseptic loosening can be analysed. For the cemented TwinSys stem mid- and long-term data is only avalible from the New Zeeland Arthroplasty ...

متن کامل

Medium-term Outcome of Cemented Titanium Stems

Early failures have seen titanium fall from favour as a material for cemented femoral stems. Between 1989 and 1994, we performed a prospective review of a consecutive series of 122 cemented total hip replacements using the Ultima straight textured titanium stem, and report the fiveto ten-year clinical and radiological outcomes. There were no revisions for loosening of the femoral stem. Revision...

متن کامل

A Single Femoral Component for All Total Hip Replacements Performed by a Trust? Does This Affect Early Clinical and Radiological Outcomes?

Background: Hospitals may be under pressure to implement cost saving strategies regarding prosthesis choice. Thismay involve the use of components which are not the first preference of individual surgeons, or those they have littleexperience with. We aim to examine the effect of standardizing the type of femoral stem used in a single trust, anddetermine whether this is safe practice, particular...

متن کامل

An evaluation of the radiological changes around the Grammont reverse geometry shoulder arthroplasty after eight to 12 years.

Radiological changes and differences between cemented and uncemented components of Grammont reverse shoulder arthroplasties (DePuy) were analysed at a mean follow-up of 9.6 years (8 to 12). Of 122 reverse shoulder arthroplasties implanted in five shoulder centres between 1993 and 2000, a total of 68 (65 patients) were available for study. The indications for reversed shoulder arthroplasty were ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 87  شماره 

صفحات  -

تاریخ انتشار 2016