Relationship between indoor and outdoor bio-aerosols collected with a button inhalable aerosol sampler in urban homes.

نویسندگان

  • T Lee
  • S A Grinshpun
  • D Martuzevicius
  • A Adhikari
  • C M Crawford
  • J Luo
  • T Reponen
چکیده

This field study investigated the relationship between indoor and outdoor concentrations of airborne actinomycetes, fungal spores, and pollen. Air samples were collected for 24 h with a button inhalable aerosol sampler inside and outside of six single-family homes located in the Cincinnati area (overall, 15 pairs of samples were taken in each home). The measurements were conducted during three seasons - spring and fall 2004, and winter 2005. The concentration of culturable actinomycetes was mostly below the detection limit. The median indoor/outdoor ratio (I/O) for actinomycetes was the highest: 2.857. The indoor of fungal and pollen concentrations followed the outdoor concentrations while indoor levels were mostly lower than the outdoor ones. The I/O ratio of total fungal spores (median=0.345) in six homes was greater than that of pollen grains (median=0.025). The low I/O ratios obtained for pollen during the peak ambient pollination season (spring) suggest that only a small fraction penetrated from outdoor to indoor environment. This is attributed to the larger size of pollen grains. Higher indoor concentration levels and variability in the I/O ratio observed for airborne fungi may be associated with indoor sources and/or higher outdoor-to-indoor penetration of fungal spores compared to pollen grains. Practical Implication This study addresses the relationship between indoor and outdoor concentrations of three different types of bio-aerosols, namely actinomycetes, fungal spores, and pollen grains. The results show that actinomycetes are rare in indoor and outdoor air in Midwest, USA. Exposure to pollen occurs mainly in the outdoor air even during peak pollen season. Unexpectedly high fungal spore concentrations were measured outdoors during winter. The presented pilot database on the inhalable levels of indoor and outdoor bio-aerosols can help apportion and better characterize the inhalation exposure to these bio-aerosols. Furthermore, the data can be incorporated into existing models to quantify the penetration of biological particles into indoor environments from outdoors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Culturability and concentration of indoor and outdoor airborne fungi in six single-family homes.

In this study, the culturability of indoor and outdoor airborne fungi was determined through long-term sampling (24-h) using a Button Personal Inhalable Aerosol Sampler. The air samples were collected during three seasons in six Cincinnati area homes that were free from moisture damage or visible mold. Cultivation and total microscopic enumeration methods were employed for the sample analysis. ...

متن کامل

Indoor Airborne Bio Aerosols in Valiasr Hospital in Zanjan, Iran

Background: Bio aerosols include airborne micro-organisms such as bacteria, fungi, viruses, etc and their products. Exposure to a bio aerosol is linked with a broad spectrum of health problems, including infectious diseases, acute toxic effects, allergies, and cancer. The aim of this study was to evaluate the quality and quantity of bio aerosols found in the air of different wards in Valiasr Ho...

متن کامل

Assessment of air pollution in exercise centers and health risks

Background: In recent years, Tehran has faced major problems with air pollution for many reasons, and this issue has become a critical point in most of the days. However, less attention has been paid to the indoor air pollutants in exercise centers and their possible health effects. In this research, it was tried to briefly describe the characteristics and chemical composition of the aerosols p...

متن کامل

Exposure to metalworking fluid aerosols and determinants of exposure.

Metalworking fluid (MWF) aerosols are associated with respiratory disorders including asthma and hypersensitivity pneumonitis. The aims of this study were to describe exposure to inhalable MWF aerosols and volatile compounds in machine shops, to estimate the influence of important determinants of exposure and to compare different sampling techniques for MWF aerosols. Personal full-shift air sam...

متن کامل

بررسی مقایسه‌ای غلظت ذرات معلق در هوای داخل با هوای آزاد خارج بیمارستان دنا شیراز

Abstract Introduction & Purpose: Indoor air quality, particularly in health care facility, is important. One of the most important factors affect the air quality is aerosols due to carrying microorganisms and deposit in the respiratory tract. Therefore, the purpose of this study was to measure the concentration of suspended particles in outdoor and indoor ‎of Dena hospital and determine the re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Indoor air

دوره 16 1  شماره 

صفحات  -

تاریخ انتشار 2006