A retrospective comparison of smart prep and test bolus multi-detector CT pulmonary angiography protocols

نویسندگان

  • Tara Suckling
  • Tony Smith
  • Warren Reed
چکیده

INTRODUCTION Optimal arterial opacification is crucial in imaging the pulmonary arteries using computed tomography (CT). This poses the challenge of precisely timing data acquisition to coincide with the transit of the contrast bolus through the pulmonary vasculature. The aim of this quality assurance exercise was to investigate if a change in CT pulmonary angiography (CTPA) scanning protocol resulted in improved opacification of the pulmonary arteries. Comparison was made between the smart prep protocol (SPP) and the test bolus protocol (TBP) for opacification in the pulmonary trunk. METHODS A total of 160 CTPA examinations (80 using each protocol) performed between January 2010 and February 2011 were assessed retrospectively. CT attenuation coefficients were measured in Hounsfield Units (HU) using regions of interest at the level of the pulmonary trunk. The average pixel value, standard deviation (SD), maximum, and minimum were recorded. For each of these variables a mean value was then calculated and compared for these two CTPA protocols. RESULTS Minimum opacification of 200 HU was achieved in 98% of the TBP sample but only 90% of the SPP sample. The average CT attenuation over the pulmonary trunk for the SPP was 329 (SD = ±21) HU, whereas for the TBP it was 396 (SD = ±22) HU (P = 0.0017). The TBP also recorded higher maximum (P = 0.0024) and minimum (P = 0.0039) levels of opacification. CONCLUSION This study has found that a TBP resulted in significantly better opacification of the pulmonary trunk than the SPP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism

Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...

متن کامل

Evaluation of the confounding factors disturbing the quality of CT images of pulmonary angiography

    Background: Since pulmonary angiography is the only non-invasive method for diagnosing pulmonary embolism, the use of radiation reduction methods without affecting the quality of images seems necessary. One of the simplest reasons for unnecessarily increasing of patient exposure is repetitive imaging due to poor image quality. Therefore, it is necessary to identify and ...

متن کامل

مقایسه یافته‌های آنژیوگرافی عروق کلیوی به روش توموگرافی کامپیوتری چندلایه با  یافته‌های جراحی در افراد زنده دهنده کلیه

Background: In kidney transplantation decision about the proper kidney donation is different between surgeons, but simple vasculature anatomy and a kidney without abnormalities are the most important reasons of choosing a kidney. Therefore    complete assessment of renal vessels of a live donor with noninvasive techniques is a necessity for nephrectomy. For delineation of the kidney vasculature...

متن کامل

Simultaneous cervical CT angiography from routine contrast-enhanced neck CT with multi-detector CT scanning

84 ● M a r t 2 0 0 1 C omputed tomographic angiography (CTA) is a technique that has evolved in a rapidly changing interplay of hardware and software advances. CT scan times are becoming ever shorter, now allowing imaging of larger segments of arterial anatomy during circulation of the intravenous bolus of contrast material. Multidetector (or multislice) CT is the most recent dramatic advance t...

متن کامل

Reducing computed tomography radiation dose in diagnosing pulmonary embolism

BACKGROUND AND OBJECTIVE Computed tomography angiography plays a major role in the diagnosis of pulmonary embolism. Radiation dose associated with it is a major concern; therefore it is important to optimize protocols and techniques to ensure minimum radiation dose. METHODS The study compares two protocols i. Conventional Timing Bolus CT protocol and Delayed Timing Bolus protocol used to assi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 60  شماره 

صفحات  -

تاریخ انتشار 2013