Comparison of two real-time quantitative assays for detection of severe acute respiratory syndrome coronavirus.
نویسندگان
چکیده
The new severe acute respiratory syndrome (SARS) coronavirus (CoV), described in February 2003, infected a total of 8,439 people. A total of 812 people died due to respiratory insufficiency. Close contact with symptomatic patients appeared to be the main route of transmission. However, potential transmission by blood transfusion could not be definitely excluded. Two real-time SARS-specific PCR assays were assessed for their sensitivities, agreement of test results, and intra-assay variabilities. Both assays rely on reverse transcription and amplification of extracted RNA. Dilutions of gamma-irradiated cell culture supernatants of SARS CoV-infected Vero E6 cells were prepared to determine the precisions, linear ranges, and accuracies of the assays. The linear range for the Artus RealArt HPA-Coronavirus assay (Artus assay) was 1 x 10(2) to 1 x 10(7) copies/ml, and that for the Roche LightCycler SARS CoV Quantification kit (Roche assay) was 1 x 10(4) to 2 x 10(8) copies/ml. The detection limit of the Roche assay was 3,982.1 copies/ml, whereas that of the Artus assay was 37.8 copies/ml. Detection limits were calculated with a standard preparation that was recommended for use by the World Health Organization. However, quantification of CoV in this preparation may be imprecise. In summary, both assays are suitable for quantitative measurement of SARS CoV at the high concentrations expected in sputum samples. The Artus assay is also suitable for detection of SARS CoV at the low concentrations found in serum samples.
منابع مشابه
Performance of single-step gel-based reverse transcription-PCR (RT-PCR) assays equivalent to that of real-time RT-PCR assays for detection of the severe acute respiratory syndrome-associated coronavirus.
Simple gel-based one-step reverse transcription-PCR (RT-PCR) assays, used to investigate patients during the 2003 severe acute respiratory syndrome (SARS) outbreak in Singapore, were found to be as sensitive as commercial and in-house real-time RT-PCR assays. The detection limit was approximately 1 genome equivalent (GE) per 5 microl PCR mixture. One PFU of SARS coronavirus was estimated to be ...
متن کاملGastrointestinal Manifestations in Patients Infected with SARS-CoV-2
Coronavirus disease 2019, caused by severe acute respiratory syndrome coronavirus 2, has recently become the number one problem affecting global health. Coronavirus disease 2019 is principally recognized by its respiratory manifestations; however, recent studies have shown an increasing number of patients with gastrointestinal complaints like diarrhea, nausea, vomiting, and abdominal discomfort...
متن کاملDetection of severe acute respiratory syndrome coronavirus in stool specimens by commercially available real-time reverse transcriptase PCR assays.
Three commercially available real-time reverse transcriptase PCR assays (the Artus RealArt HPA coronavirus LightCycler, the Artus RealArt HPA coronavirus Rotor-Gene, and the EraGen severe acute respiratory syndrome coronavirus POL assay) and three RNA extraction methodologies were evaluated for the detection of severe acute respiratory syndrome coronavirus RNA from 91 stool specimens. The assay...
متن کاملDetection of severe acute respiratory syndrome coronavirus in blood of infected patients.
Severe acute respiratory syndrome (SARS) has caused major outbreaks worldwide, resulting in an urgent need to obtain sensitive and accurate diagnosis of this disease. PCR-based detection methods were developed for use on a variety of samples, including blood. Eighteen subjects were investigated, and results indicated that blood samples contain sufficient virus for detection by using quantitativ...
متن کاملPreclinical evaluation of two real-time, reverse transcription-PCR assays for detection of the severe acute respiratory syndrome coronavirus.
We verified the analytical performance characteristics of a previously described real-time reverse transcription-PCR (RT-PCR) assay targeting the open reading frame (ORF) 1b region of the severe acute respiratory syndrome coronavirus (SARS-CoV) with RNA transcripts. We then compared it to a novel nucleocapsid gene real-time RT-PCR assay with genomic RNA. The assays differed only in the primer a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 42 5 شماره
صفحات -
تاریخ انتشار 2004