Influence of static magnetic fields on pain perception and sympathetic nerve activity in humans.
نویسندگان
چکیده
Static and pulsed magnetic fields have been reported to have a variety of physiological effects. However, the effect of static magnetic fields on pain perception and sympathetic function is equivocal. To address this question, we measured pain perception during reproducible noxious stimuli during acute exposure to static magnets. Pain perception, muscle sympathetic nerve activity, mean arterial pressure, heart rate, and forearm blood velocity were measured during rest, isometric handgrip, postexercise muscle ischemia, and cold pressor test during magnet and placebo exposure in 15 subjects (25 +/- 1 yr; 8 men and 7 women) following 1 h of exposure. During magnet exposure, subjects were placed on a mattress with 95 evenly spaced 0.06-T magnets imbedded in it. During placebo exposure, subjects were placed on an identical mattress without magnets. The order of the two exposure conditions was randomized. At rest, no significant differences were noted in muscle sympathetic nerve activity (8 +/- 1 and 7 +/- 1 bursts/min for magnet and placebo, respectively), mean arterial pressure (91 +/- 3 and 93 +/- 3 mmHg), heart rate (63 +/- 2 and 62 +/- 2 beats/min), and forearm blood velocity (3.0 +/- 0.3 and 2.6 +/- 0.3 cm/s). Magnets did not alter pain perception during the three stimuli. During all interventions, no significant differences between exposure conditions were found in muscle sympathetic nerve activity and hemodynamic measurements. These results indicate that acute exposure to static magnetic fields does not alter pain perception, sympathetic function, and hemodynamics at rest or during noxious stimuli.
منابع مشابه
Effects of static and electromagnetic fields on human serum paraoxonase-1 activity in vitro
Introduction: In recent years the relationship between electromagnetic fields and coronary artery disease is attracted a considerable attention. Low density lipoprotein (LDL) oxidation is the initial step in the development of atherosclerosis. Paraoxonase1 (PON1) protects LDL and High density lipoprotein (HDL) against oxidative processes, thus preventing the formation of atherogenic (oxidized-L...
متن کاملDoes Exposure to Static Magnetic Fields Generated by Magnetic Resonance Imaging Scanners Raise Safety Problems for Personnel?
MRI workers are occupationally exposed to static and time-varying gradient magnetic fields. While the 24-hour time-averaged exposure to static magnetic fields is about a few mT, the maximum static field strength can be as high as 500 mT during patient setup. Over the past several years, our laboratory has performed extensive experiments on the health effects of exposure of animal models and h...
متن کاملEffects of magnetic fields on the seed germination and metabolism in two specious of Almond
During the past decade considerable evidence has been accumulated with regard to the biological effects, both in vivo and in vitro, of extremely low frequency electric and magnetic fields, such as those originating from residentially proximate power lines, household electrical wiring and diagnostic apparatus and therapy devices. Also, during the evolution process, all living organisms experienc...
متن کاملA randomized controlled trial of the effects of a combination of static and dynamic magnetic fields on carpal tunnel syndrome.
OBJECTIVE To determine if a physics-based combination of simultaneous static and time-varying dynamic magnetic field stimulation to the wrist 4 hours/day for 2 months can reduce subjective neuropathic pain and influence objective electrophysiologic parameters of patients with carpal tunnel syndrome (CTS). METHODS Randomized, double-blinded, placebo-controlled trial of 36 symptomatic hands. Pr...
متن کاملMicroneurographic studies of the mechanisms of sympathetic nerve responses to static exercise in humans.
The purpose of this study was to determine the contribution of muscle afferents and central command in regulating sympathetic nerve activity during static exercise in humans. In 20 healthy subjects, we recorded heart rate, arterial pressure, and efferent sympathetic nerve activity in the leg during arm exercise. Microelectrodes were inserted percutaneously into a fascicle of the peroneal nerve ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 102 4 شماره
صفحات -
تاریخ انتشار 2007