The effects of custom tray material on the accuracy of master casts.

نویسندگان

  • L J Martinez
  • J A von Fraunhofer
چکیده

PURPOSE The accuracy of master cast reproduction by a polyvinylsiloxane impression material using two visible-light-curing resin and an autopolymerizing polymethyl methacrylate resin custom tray materials was investigated. MATERIALS AND METHODS Custom trays were fabricated from a master cast that had three index points marked on both the inner and outer vestibules. Impressions were made of the master cast using Extrude and then poured in Die Keen Green stone. The distances between the reproduced index points were measured to +/- 0.01 mm with a traveling microscope and the algebraic norms calculated for each tray material. RESULTS No differences (p > .05) were found in the dimensions of the inner index points, while the separations of the outer index points indicated that there were differences in the accuracy of reproduction (p < .01) by the three tray materials. The index points reproduced on the casts, compared with the master cast, were closer together for the Triad Blue trays than for the TruTray and Ontray impression trays. CONCLUSIONS All three tray materials produced acceptable casts, but the greatest accuracy was achieved with TruTray, followed by Ontray. Triad Blue produced casts that were slightly smaller than the master. In practice, the small measured differences in cast dimensions may not have clinical significance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In Vitro Comparative Evaluation of Different Types of Impression Trays and Impression Materials on the Accuracy of Open Tray Implant Impressions: A Pilot Study

Purpose. For a precise fit of multiple implant framework, having an accurate definitive cast is imperative. The present study evaluated dimensional accuracy of master casts obtained using different impression trays and materials with open tray impression technique. Materials and Methods. A machined aluminum reference model with four parallel implant analogues was fabricated. Forty implant level...

متن کامل

Comparison of implant cast accuracy of multiple implant impression technique with different splinting materials: An in vitro study

INTRODUCTION An accurate and passive fit of implant framework prosthesis, as well as the successful surgical operation is suggested as one of the critical requirements for long-term implant success. OBJECTIVE The purpose of this in vitro study was to evaluate the accuracy of the master cast using open tray impression technique with conventional and novel splinting materials. METHODOLOGY A m...

متن کامل

Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique

PURPOSE To compare the dimensional accuracy of three impression techniques- a separating foil impression, a custom tray impression, and a stock tray impression. MATERIALS AND METHODS A machined mandibular complete-arch metal model with special modifications served as a master cast. Three different impression techniques (n = 6 in each group) were performed with addition-cured silicon materials...

متن کامل

Comparative Evaluation of the Dimensional Accuracy of Different Putty-Wash Techniques Using Additional Silicon Impression Material In Vitro Study

Purpose: The aim of the present study was to evaluate and compare the dimensional accuracy of stone models made by addition silicone impression material using three puttywash impression techniques: one step putty wash (dual viscosity), two step and modified two step putty wash technique. Material and Methods: A stainless steel master model was constructed simulating a three-unit fixed prosthesi...

متن کامل

Effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts

BACKGROUND Different factors such as impression techniques and materials can affect the passive fit between the superstructure and implant. The aim of this study was to determine the effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts. MATERIALS AND METHODS Four internal hex implants (Biohorizons Ø4 mm) were placed on a metal maxilla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of prosthodontics : official journal of the American College of Prosthodontists

دوره 7 2  شماره 

صفحات  -

تاریخ انتشار 1998