In situ imaging of the mouse cochlea using two-photon microscopy

نویسندگان

  • Xin Yang
  • Ye Pu
  • Demetri Psaltis
  • Konstantina M. Stankovic
چکیده

Intracochlear imaging is of great interest clinically because cochlea is the central organ of hearing. However, intracochlear imaging is technologically challenging due to the cochlea’s small size and encasement in bone. The stateof-the-art imaging techniques are not adequate for high resolution cellular imaging to establish diagnosis without destroying the cochlea. We report in situ imaging of intact mouse cochlea using endogenous two-photon excitation fluorescence (TPEF) as the contrast mechanism. TPEF eliminates the need for exogenous labeling and eradicating the staining-induced artifacts. We used a natural, membranous opening into the cochlea, the round window, as the optical access to reach the organ of Corti, requiring no additional slicing or opening. Our approach provides the maximum non-invasiveness in the imaging process. TPEF exhibits strong contrast allowing deep imaging of mouse cochlea with cellular and even subcellular resolution. Inner hair cell, outer hair cell and supporting cell are clearly identifiable in TPEF images. Distinct morphological differences are observed between healthy and noise-exposed cochleae, allowing detection of specific, noise-induced pathologic changes. The TPEF images taken through the round window are correlated with the whole mount sections, verifying their reliability. Compared with one-photon excitation fluorescence (OPEF) confocal microscope and wide-field transmission microscope images taken under the same magnification and resolution, TPEF images demonstrate clear advantages in terms of sharpness, signal to noise ratio and contrast. These capabilities provide a working foundation for microendoscopy-based clinical diagnostics of sensorineural hearing loss.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two-photon microscopy of the mouse cochlea in situ for cellular diagnosis.

Sensorineural hearing loss is the most common type of hearing loss worldwide, yet the underlying cause is typically unknown because the inner ear cannot be biopsied today without destroying hearing, and intracochlear cells have not been imaged with resolution sufficient to establish diagnosis. Intracochlear imaging has been technologically challenging because of the cochlea's small size and enc...

متن کامل

Nonlinear Optical Properties of Rigid Polyurethane Foam/SiO2 Nanocomposite

Polyurethane closed cell (PUCC)/SiO2 nanocomposites have been prepared by using in situ polymerization approach. The third-order optical nonlinearities of PUCC/SiO2 nanocomposites, dissolved in DMF are characterized by Z-scan technique at the measurement wavelength of 532 nm. The nonlinear refractive (NLR) indices and nonlinear absorption (NLA) coefficients of samples were calculated from close...

متن کامل

Calcium imaging of inner ear hair cells within the cochlear epithelium of mice using two-photon microscopy.

Mice are an excellent model for studying mammalian hearing and transgenic mouse models of human hearing, loss are commonly available. However, the mouse cochlea is substantially smaller than other animal models routinely used to study cochlear physiology. This makes study of their hair cells difficult. We develop a novel methodology to optically image calcium within living hair cells left undis...

متن کامل

Neural Imaging Using Single-Photon Avalanche Diodes

Introduction: This paper analyses the ability of single-photon avalanche diodes (SPADs) for neural imaging. The current trend in the production of SPADs moves toward the minimumdark count rate (DCR) and maximum photon detection probability (PDP). Moreover, the jitter response which is the main measurement characteristic for the timing uncertainty is progressing. Methods: The neural imaging pro...

متن کامل

In vivo two-photon microscopy to 1.6-mm depth in mouse cortex.

Deep tissue in vivo two-photon fluorescence imaging of cortical vasculature in a mouse brain using 1280-nm excitation is presented. A record imaging depth of 1.6 mm in mouse cortex is achieved in vivo, approximately reaching the fundamental depth limit in scattering tissue.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015