An evaluation of the fit of metal-ceramic restorations made with an autoclaved silicone-based impression material.
نویسندگان
چکیده
AIM To demonstrate the clinical feasibility of autoclaving certain silicone impression materials in order to avoid potential cross-contamination during handling, transport, and subsequent processing. BACKGROUND Semicritical devices are recommended to be treated at least with high-level disinfectants or actually steam sterilized at 134°C. To date dental impressions have been disinfected rather than sterilized, so the question remains should they be sterilized before being sent to the dental laboratory? CASE DESCRIPTIONS Two identical impressions per case were made of metal-ceramic crown and fixed partial denture preparations on the same patient using addition type polyvinyl siloxane (PVS) impression materials (AFFINIS,® Coltene/Whaledent AG, 9450 Altstätten, Switzerland) in different trays. The first impression (IMPx1) was cleaned and treated with an intermediate-level disinfectant (FD 322--Fast Disinfection Spray, Dürr Dental, 74321 Bietigheim-Bissingen, Germany). The second impression (IMPx2) was cleaned, treated with an intermediate-level disinfectant as with IMPx1, subjected to a computer tomography (CT) scan with a dimensional resolution of ± 10 µm, steam sterilized, and then subjected to a second CT scan. The dimensional changes of the second impression after steam sterilization were calculated by comparing the overlay of the two CT scans and expressed by color coding of the impression graphics. After the second scan, the impression was sent to a dental laboratory to fabricate a metal-ceramic crown or metal-ceramic fixed partial denture restoration to the one produced from the first impression (IMPx1) subjected only to disinfection. This process was repeated for four clinical cases. CONCLUSION Impressions made with AFFINIS® silicone impression materials in a rigid reinforced polycarbonate impression tray or in a metal dual-arch tray can be autoclaved. The overall dimensional stability of the impressions and the quality of single crowns and small fixed partial dentures made using IMPx2 was not compromised. The maximum dimensional differences at the preparations of the nonautoclaved and the autoclaved impressions were found to be within acceptable limits of about 50-100 µm. CLINICAL SIGNIFICANCE Steam sterilization of AFFINIS® impressions is possible without adversely affecting dimensional change. In addition, clinicians can clearly indicate to the dental practice and laboratory personnel that sterilization of the impressions has been performed, cross-contamination is unlikely, and the impressions present no apparent health hazard during transport and subsequent processing.
منابع مشابه
Comparative Analysis of Dimensional Accuracy of Two Types of Silicone Impression Materials: Optosil and Elite-HD
Statement of the Problem: Understanding about impression materials, their properties, uses and manipulation can guide operators towards having more successful restorations. Purpose: The aim of this in vitro study was to compare the accuracy of a condensation silicone impression material, Optosil, and an addition poly siloxane impression material, Elite-HD. Materials and Method: A laboratory mod...
متن کاملThe evaluation and comparison of marginal adaptation in metal ceramic and all ceramic restorations fabricated by two methods: CAD/CAM and conventional
Introduction: Marginal fit is a key factor for long term clinical success through any dental restorations. Poor marginal adaptation causes cement dissolution. This can lead to dental caries, gingival irritation, periodontal diseases, and finally treatment failure. The aim of this study was measurement and comparison of marginal gap quantities in metal ceramic and all ceramic dental restorations...
متن کاملMarginal fit of leucite-glass pressable ceramic restorations and ceramic-pressed-to-metal restorations.
STATEMENT OF PROBLEM Fabricating a feldspathic porcelain margin on a metal-ceramic restoration with a clinically acceptable marginal fit has proven to be a technique-sensitive procedure. Pressable ceramics are advocated to solve this problem. PURPOSE The purpose of this in vitro study was to compare the marginal adaptation of a pressable ceramic system when used with both all-ceramic and meta...
متن کاملProcessing Capability of Apatite-Mullite Glass-Ceramic Materials for the Production of Dental Restorations
Introduction: There is currently significant interest in all-ceramic dental restorations. A potential non-metallic material for such restorations is an apatite-mullite glass-ceramic that could be processed to shape using different processing techniques. The aim of this study was to assess and evaluate the ability of an apatite-mullite glass-ceramic material to be processed using three routes: l...
متن کاملDimensional Accuracy of Polyvinyl Siloxane Impression Materials Considering Impression Techniques– A Literature Review
Objectives Impression accuracy is the main determinant of the fit, form and function of prosthetic restorations. Polyvinyl siloxane (PVS) is the material of choice in most clinical situations. The purpose of this paper is to provide an up-to-date review of scientific articles which discuss the dimensional accuracy of PVS impression material using various impression techniques, tray types and sp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of contemporary dental practice
دوره 11 4 شماره
صفحات -
تاریخ انتشار 2010