Consensus on Microembolus Detection by TCD

نویسندگان

  • David H. Evans
  • Donald G. Grosset
چکیده

Transcranial Doppler ultrasound is capable of detecting microembolic material, both gaseous and solid, within the intracranial cerebral arteries. To avoid discrediting this promising and exciting new technique, experts in this field met in January 1997 in Frankfurt, Germany, to discuss the limitations and problems of embolus detection and to determine guidelines for its proper use in clinical practice, as well as in scientific investigations. In particular, the authors suggest that studies report the following parameters: (1) ultrasound device, (2) transducer type and size, (3) insonated artery, (4) insonation depth, (5) algorithms for signal intensity measurement, (6) scale settings, (7) detection threshold, (8) axial extension of sample volume, (9) fast Fourier transform (FFT) size (number of points used), (10) FFT length (time), (11) FFT overlap, (12) transmitted ultrasound frequency, (13) high-pass filter settings, and (14) recording time. There was agreement that no current system of automatic embolus detection has the required sensitivity and specificity for clinical use. (Stroke. 1998;29:725-729.)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microembolus detection in patients with Takayasu's arteritis.

BACKGROUND AND PURPOSE Takayasu's arteritis (TA) is a chronic inflammatory disease of unknown etiology that can affect the aorta and its branches. The cerebral ischemia in TA can be caused by a variety of mechanisms, and the focus of this study is to detect the possible contribution of microembolus in the pathogenesis of stroke. METHODS Eighteen patients with TA according to the criteria for ...

متن کامل

Identifying which patients with asymptomatic carotid stenosis could benefit from intervention.

C arotid guidelines recommend carotid endarterectomy (CEA) for patients with 60% to 99% asymptomatic carotid stenosis (ACS) provided the perioperative stroke/death rates are <3%. Several reports have noted that the average annual risk of ipsilateral/any territory stroke among patients with asymptomatic moderate to severe internal carotid artery stenosis receiving medical therapy (MT) alone has ...

متن کامل

Microembolic Signals Detected with Transcranial Doppler Sonography Differ between Symptomatic and Asymptomatic Middle Cerebral Artery Stenoses in Northeast China

Although microembolus monitoring has been widely used for ischemic cerebrovascular disease, the clinical significance of microembolic signal (MES) in asymptomatic middle cerebral artery (MCA) stenosis remains unclear. We aim to investigate the frequency of MES and the value of MES in predicting ischemic stroke secondary to asymptomatic MCA stenosis. From June 2011 to December 2012, microembolus...

متن کامل

Contrast transcranial Doppler compared to transesophageal echocardiography in detection of right-to-left shunt.

OBJECTIVE To assess contrast transcranial Doppler (TCD) for detection of right-to-left shunt (RLSh). METHODS We studied 30 patients aged between 25-45 years admitted to Al-Zahra Hospital, affiliated to Isfahan University of Medical Sciences, between May 2003 and May 2005. All patients underwent transesophageal echocardiography (TEE) with contrast and contrast TCD. RESULTS Eleven (36.6%) pat...

متن کامل

Clinical significance of microembolus detection by transcranial Doppler sonography in cardiovascular clinical conditions.

Transcranial Doppler can detect microembolic signals, which are characterized by unidirectional high intensity increase, short duration, and random occurrence, producing a "whistling" sound. Microembolic signals have been proven to represent solid or gaseous particles within the blood flow. Microemboli have been detected in a number of clinical cardiovascular settings: carotid artery stenosis, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998