Diastolic murmurs in the presence of Starr-Edwards mitral prosthesis.
نویسندگان
چکیده
Diastolic murmurs associated with the Starr-Edwards mitral prosthesis have not been described previously. In this report, five patients with mitral prostheses are described in whom apical mid-diastolic and presystolic murmurs resulted from two different causes. Three patients had clots obstructing the prosthetic orifice. The other two had normally functioning protheses and moderately severe aortic insufficiency. The occurrence of mid-diastolic and presystolic murmurs in the presence of a normally functioning prosthetic mitral valve demonstrates that 1) the mid-diastolic Austin Flint murmur can occur in the absence of incomplete mitral valve opening, premature mitral valve closure, vibrating mitral leaflets, or relative mitral stenosis and 2) the presystolic Austin Flint murmur can occur in the absence of incomplete valve opening or presystolic mitral regurgitation. However, the presystolic murmur was associated with early closure movement of the presthetic poppet.
منابع مشابه
Double Valve Replacement (Mitral and Aortic) for Rheumatic Heart Disease: A 20-year experience with 300 patients.
Introduction: Rheumatic heart disease still remains one of the leading causes of congestive heart failure and death owing to valvular pathologies, in developing countries. Valve replacement still remains the treatment of choice in such patients.The aim of this study wasto analyze the postoperative outcome of double valve replacement (Mitral and Aortic ) in patients of rheumatic heart disease. ...
متن کاملMitral Ball-Valve Prosthesis
REPLACEMENT of nonfunctioning valves is a significant recent advancement in the correction of cardiac valvular disease. The most widely used artificial device replacing the mitral valve is the Starr-Edwards ballvalve prosthesis.' Its effectiveness was shown in recent reports by the marked clinical improvement in properly selected patients.2 However, cardiologists and cardiac surgeons are faced ...
متن کاملAnalysis of dynamics of mitral Starr-Edwards valve prosthesis using reflected ultrasound.
The speed of closure of the mitral valve during diastole, as recorded by ultrasonocardiography, is reduced in patients with mitral stenosis. A pattern of movement similar to that of severe mitral stenosis is seen in recordingsfrom patients with normally functioning mitral Starr-Edwards prostheses. Simultaneous ultrasound recordings of ball and cage movements show that the prosthetic valve remai...
متن کاملFatal thrombosis of the Starr-Edwards mitral valve prosthesis associated with bacterial endocarditis. Diagnostic significance of a disappearing prosthetic click.
A case of fatal thrombosis of Starr-Edwards mitral valve prosthesis associated with bacterial endocarditis is presented. The role of inadequate anticoagulation and bacterial endocarditis in the formation of massive thrombus on the valve prosthesis is discussed. The detection of disappearance of a dLstinct click sound in a patient with a previously functioning Starr-Edwards mitral valve prosthes...
متن کاملHaemolysis with Björk-Shiley and Starr-Edwards prosthetic heart valves: a comparative study.
Slater, S. D., Saflam, I. A., Bain, W. H., Turner, M. A., and Lawrie, T. D. V. (1974). Thorax, 29, 624-632. Haemolysis with Bjork-Shiley and Starr-Edwards prosthetic heart valves: a comparative study. A comparison was made of the haemolytic complications in 85 patients with two different types of Starr-Edwards cloth-covered ball and cage prosthesis with those in 44 patients with the Bjork-Shile...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 51 3 شماره
صفحات -
تاریخ انتشار 1975