Comparison of two-point (AutoAnalyzer II) with kinetic methods for transaminase assay.
نویسندگان
چکیده
The general performance of the Technicon AutoAnalyzer II method for the routine estimation of serum aspartate and alanine transaminase has been assessed and compared with that of the LKB reaction rate analyser. The results of the two methods correlate, there is little difference in precision, and running costs are comparable. Some of the relative advantages of the two types of analysis are discussed.
منابع مشابه
A continuous-flow (AutoAnalyzer II) procedure for measuring erythrocyte transketolase activity.
In this semiautomated method, an AutoAnalyzer II is used to measure the enzymic production of glyceraldehyde 3-phosphate in hemolysates, to assay erythrocyte transketolase (EC 2.2.1.1) activity. Hemolysate and indicator reactions are separated by dialysis to eliminate hemoglobin interference and increase sensitivity. Internal standards of glyceraldehyde 3-phosphate in hemolysate carriers were q...
متن کاملAutomated method for determination of penicillins, cephalosporins, and penicillinases.
The microiodometric assay of Novick for penicillinase was adapted to the Technicon Autoanalyzer system. With this automated method, it is possible to analyze almost 60 samples per hr. Two different procedures are described: in the first, the samples were incubated with substrate in the machine under standardized conditions; in the second, samples were incubated outside the Autoanalyzer and assa...
متن کاملKinetic serum creatinine assays. II. A critical evaluation and review.
We have evaluated the Technicon AutoAnalyzer method, the Beckman Creatinine Analyzer II, DuPont aca, Electro-Nucleonics GEMSAEC, and Instrumentation Laboratory Model 916 kinetic methods for determination of serum creatinine. These methods, which involve the Jaffé reaction, all showed a statistically significant proportional error relative to an ion-exchange pretreatment method for creatinine in...
متن کاملMicrotitre plate method for alanine transferase (ALT) assays.
A kinetic assay for alanine transferase (ALT) using microtitre plates and commercially available reagents was developed to retain the advantages conferred by multichannel and semiautomated equipment. The time taken to assay 92 samples was less than 10 minutes, and costs of apparatus and reagents compared favourably with most current methods. Although reactions became non-linear above 120 IU/l-1...
متن کاملComparison of One-point and Two-point Methods for Estimation of Infiltration Parameters in Furrow Irrigation
Infiltration is one of the most important hydraulic parameters affecting surface irrigation and one ofthe most difficult parameters in practical field determinations. The infiltration equations are used todescribe water flow hydraulics and surface irrigation systems design. But determination of theparameters in these equations are costly and time consuming. Therefore, some estimating methods ar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 26 1 شماره
صفحات -
تاریخ انتشار 1973