Intraoperative factors associated with stranded source placement accuracy in low-dose-rate prostate brachytherapy.

نویسندگان

  • M F Jamaluddin
  • S Ghosh
  • M P Waine
  • M Tavakoli
  • J Amanie
  • A D Murtha
  • D Yee
  • N Usmani
چکیده

PURPOSE The quality of a low-dose rate prostate brachytherapy implant depends on the accurate placement of sources in their planned locations. This study investigates intraoperative factors that potentially contribute to stranded source placement inaccuracy in prostate brachytherapy. METHODS AND MATERIALS Intraoperative video images of the brachytherapist's hand motions and needle insertions during the implant procedure were acquired for analysis. Using video analysis software, maximum and average needle insertion velocities were determined. The number of needle insertion attempts and the use of the brachytherapist's other hand to manipulate the needle direction were also recorded. Sources misplacements were analyzed using an ultrasound-based method described elsewhere. RESULTS Fifteen patients agreed to undergo this study; 1619 125I seeds were inserted using 357 needles; 1197 seeds were confidently identified using ultrasound images and included in the analysis. The mean overall misplacement was 0.49 cm (0-2 cm, 95% CI = 0.47-0.51); 614 seeds were delivered with a single pass and 583 seeds with >1 passes (range 2-6). The mean maximum needle velocity was 12.34 cm s-1 (range 4-28 cm s-1) and mean average velocity was 4.76 cm s-1 (range 0.4-17.4 cm s-1); 747 seeds were delivered with manipulation of the needle. The generalized linear model test was used to analyze factors contributing to seed misplacement, and it was found that a maximum speed <12 cm s-1 was associated with a decrease in seed misplacement by 0.049 cm vs. a maximum speed >12 cm s-1, p = 0.0121). Other evaluated factors were found to have no statistically significant correlation with seed misplacement: average speed (p = 0.4947), manual manipulation of needle (p = 0.9264), and number of needle passes (p = 0.8907). CONCLUSIONS This study identified that needles inserted with lower maximum velocity were associated with less seed misplacement. Manual manipulation of the needle, number of passes, and average speed did not show statistically significant correlation with seed misplacement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Dosimetric Characteristics of IrSeed 125I Brachytherapy Source

Introduction Low dose rate brachytherapy sources have been widely used for interstitial implants in tumor sites, particularly in prostate. Dosimetric characteristics of a new IrSeed 125I brachytherapy source have been determined using the LiF thermoluminescent dosimeter (TLD) chips. Materials and Methods Dose rate constant, radial dose function, and anisotropy function around the IrSeed 125I so...

متن کامل

Brachytherapy boost techniques for locally advanced prostate cancer.

Brachytherapy boosts in combination with external-beam radiation therapy allow a highly conformal dose of radiation to be delivered to the prostate in a safe, efficient manner. Several types of brachytherapy boost techniques are used currently. Techniques based on transrectal ultrasound (TRUS) guidance clearly provide the most accurate method of radioactive source placement with reduced toxicit...

متن کامل

Perioperative Search for Circulating Tumor Cells in Patients Undergoing Prostate Brachytherapy for Clinically Nonmetastatic Prostate Cancer

Despite the absence of local prostate cancer recurrence, some patients develop distant metastases after prostate brachytherapy. We evaluate whether prostate brachytherapy procedures have a potential risk for hematogenous spillage of prostate cancer cells. Fifty-nine patients who were undergoing high-dose-rate (HDR) or low-dose-rate (LDR) brachytherapy participated in this prospective study. Thi...

متن کامل

Historical review of interstitial prostate brachytherapy

In the recent years, interstitial brachytherapy implantation has become the treatment of choice for early stage prostate cancer patients. Treatment of prostate cancer with radiation is traced back to 1909. Originally this treatment modality was very crude and could not gain much popularity till 1982. Advancements in radioactive source designs, introduction of new low energy radioactive sources,...

متن کامل

Assessment of absorbed dose uncertainty of prostate due to source relocating in brachytherapy by monte carlo method

Brachytherapy, is a method to treat prostate cancer in which a radiation source is placed inside or next to the cancer affected tissues. Purpose of this article is to determine the uncertainty level of received dose in prostate tissue due to the relocation of the placed radiation sources and inflation in prostate after positioning the radiation seeds. To simulate the model 6711 Amersham (activi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brachytherapy

دوره 16 3  شماره 

صفحات  -

تاریخ انتشار 2017