Feasibility of small bowel flow rate measurement with MRI.
نویسندگان
چکیده
OBJECTIVE To evaluate whether it is feasible to measure the segmental flux of small bowel content using MR phase-contrast (PC) pulse sequences. MATERIALS AND METHODS Using a phantom the accuracy of flux measurements was validated. Afterwards, 10 volunteers were included in a prospective clinical trial. To provide standardized small bowel distension, all volunteers ingested four equal portions of 400 mL of water doped with 5 mL gadoterate and 5.8 g Metamucil mite. The MR protocol covering the sagittal cross-sections of the small bowel included several two-dimensional (2D) PC sequences with a velocity encoding of 7 cm/second at a temporal resolution of 0.55 second. As proof of concept time-dependent flux was measured after intravenous (i.v.) administration of a spasmolytic agent in one volunteer. RESULTS Phantom measurements resulted in an excellent correlation between pump and PC measured flow rates (R = 0.999). Time-resolved small bowel flux was successfully measured in distended small bowel loops of all volunteers. A mean flow rate of 0.188 mL/second (standard deviation +/- 0.144 mL/second) was documented. The flux plots presented a sinus wave-like shape with regular aboral and oral flow. A spasmolytic effect both on flux and motility could be shown with residual flux despite complete arrest of small bowel motility. CONCLUSION PC MRI allows time-resolved in vivo measurement of small bowel flux in single well-distended bowel loops filled with gadolinium-doped aqueous solution.
منابع مشابه
3-D Modeling and Virtual Endoscopy of the Small Bowel Based on MR Imaging in Patients with Inflammatory Bowel Disease Investigative Radiology 2002;37(9):528-533
Rationale and Objectives: Small bowel MRI (Magnetic Resonance Imaging) is a new imaging modality which excellently depicts small intestine pathology in patients with inflammatory bowel disease. Virtual endoscopy based on sectional imaging is a recently introduced technique to create endoscopy like views. The aim of this study was to evaluate the feasibility of virtual small bowel endoscopy base...
متن کاملThe Role of Appendix in the Management of Biliary Atresia Associated with Bowel Atresia
Biliary atresia is characterized by the progressive obliteration of extra- and intrahepatic biliary duct system leading to the obstruction of bile flow in infancy. The cause(s) of biliary atresia remain unclear and many surgical options for bypassing the atretic segment have been described.1-3 Biliary atresia may be associated with small bowel atresia. The surgical interventions for biliary dr...
متن کاملLaparoscopic Management of Strangulated Broad Ligament Hernia
Introduction: Broad ligament hernia was first reported post-autopsy by Quain in 1861. In a 1995 review article, only 61 cases had ever been reported. This paper presents a case report of broad ligament hernia and explores the literature surrounding this topic. Case Presentation: The patient presented with no significant past medical history, acute lower a...
متن کاملPressure gradient measurement using phase contrast (PC)-MRI in stenotic phantom models: Towards noninvasive quantification of fractional flow reserve in the coronary arteries
Background Fractional flow reserve (FFR) is an invasive diagnostic tool to evaluate the functional significance of an intermediate coronary stenosis by quantifying the pressure gradient (ΔP) across that stenosis [1]. Noninvasive ΔP measurement (ΔPMR) using phase-contrast (PC)-MRI in conjunction with Navier-Stokes (NS) equations has been attempted in large to medium size vessels [2-4], and recen...
متن کاملA new method to quantify coronary flow conditions using dynamically scaled in vitro phase contrast magnetic resonance imaging
Background Atherosclerotic coronary artery disease remains a major cause of illness and death, and coronary flow predetermines disease. Limitations in imaging technology prevent coronary flow measurements but computational fluid dynamics (CFD) need sophisticated boundary conditions for accurate flow predictions. MRI has recently been combined with CFD for larger calibre vessels, but small coron...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 32 2 شماره
صفحات -
تاریخ انتشار 2010