Rapid and Reliable Calibration of Laser Beam Deflection System for Microcantilever-Based Sensor Setups
نویسندگان
چکیده
Cantilever array-based sensor devices widely utilise the laser-based optical deflection method for measuring static cantilever deflections mostly with home-built devices with individual geometries. In contrast to scanning probe microscopes, cantilever array devices have no additional positioning device like a piezo stage. As the cantilevers are used in more and more sensitive measurements, it is important to have a simple, rapid, and reliable calibration relating the deflection of the cantilever to the change in position measured by the position-sensitive detector. We present here a simple method for calibrating such systems utilising commercially available AFM cantilevers and the equipartition theorem.
منابع مشابه
Imaging the surface stress and vibration modes of a microcantilever by laser beam deflection microscopy.
There is a need for noninvasive techniques for simultaneous imaging of the stress and vibration mode shapes of nanomechanical systems in the fields of scanning probe microscopy, nanomechanical biological and chemical sensors and the semiconductor industry. Here we show a novel technique that combines a scanning laser, the beam deflection method and digital multifrequency excitation and analysis...
متن کاملDesign Simulation and Analysis of Polysilicon- based CMOS Micromachined Piezoresistive Microcantilever for Glucose Sensing
The measurement of glucose is of great importance in clinical diagnosis. This is especially essential for the continuous monitoring for example in a patient suffering from diabetes mellitus which is caused by the high levels of glucose in human physiological fluid. Even though many research have been done for glucose measurement, there are still many research in progress to develop new methods ...
متن کاملA high frequency sensor for optical beam deflection atomic force microscopy.
We demonstrate a novel electronic readout for quadrant photodiode based optical beam deflection setups. In our readout, the signals used to calculate the deflections remain as currents, instead of undergoing an immediate conversion to voltages. Bipolar current mirrors are used to perform all mathematical operations at the transistor level, including the signal normalizing division. This method ...
متن کاملCalculation of Stress And Deflection In Double Layer Microcantilever For Biosensor Application
In microcantilever-based biosensor, a sensitive layer plays an important role as a place for the establishment of functional layer for detecting molecules target. When a sensitive layer is coated on the microcantilever surface, a surface stress change is induced as a consequence of adsorbate-surface interaction, resulting in a deflection of the microcantilever. However, the microcantilever with...
متن کاملA novel mechano-optical sensor based on read-out with a Si3N4 grated waveguide
Microcantilever-based sensors can be used to detect molecular absorption of, for example, hydrogen gas, which causes changes in the surface stress, leading to deflection of the cantilever. Such a deflection can be determined by means of optical beam deflection, capacitance-, or piezo-resistance based readout. We have recently proposed a compact integrated mechano-optical sensor using a novel an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- J. Sensors
دوره 2012 شماره
صفحات -