Characteristics and SPICE simulation of a single - sided , n + on n Si strip detector before and after neutron irradiation

نویسندگان

  • M. M. Angarano
  • A. Bader
  • D. Creanza
  • M. de Palma
  • D. Diacono
  • S. My
  • G. Raso
  • P. Tempesta
چکیده

Capacitance, resistance and current measurements were carried out on single-sided, n + on n silicon strip detectors. We studied the type inversion after irradiating the detectors with neutron fluences up to 8:3 10 13 neutron=cm 2. To understand the macroscopic irradiation effects, a SPICE model of the detector was developed. By modelling the setup of the capacitance measurements, our model was able to reproduce the measured frequency dependence of the relevant capacitances both for non-irradiated and irradiated detectors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Tests of the Silicon Sensors for the ZEUS Micro Vertex Detector

To fully exploit the HERA-II upgrade, the ZEUS experiment has installed a Micro Vertex Detector (MVD) using n-type, single-sided, silicon μ-strip sensors with capacitive charge division. The sensors have a readout pitch of 120 μm, with five intermediate strips (20 μm strip pitch). The designs of the silicon sensors and of the test structures used to verify the technological parameters, are pres...

متن کامل

Irradiation with Neutrons and Formation of Simple Radiation Defects in Semiconductors

In this research, cobalt and nickel sulfide nanoparticles (NPs) were grown on AlMCM-41 matrix by using ion exchange method. The prepared samples were irradiated by thermalized neutron that emitted from Am-Be source up to fluencies (7.9+E9n/cm2). After that, X-ray diffraction (XRD), UV-Vis spectroscopy, Fourier transform...

متن کامل

Simulation of a Neutron Detector for Real Time Imaging Applications

Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...

متن کامل

Beam test results on n on n type silicon microstrip detectors before and after neutron irradiation

We present beam test results on AC-coupled, single-sided, n-on-n type silicon microstrip detectors. We have tested the detectors before and after irradiation at a fluence of 8.3× 10 n/cm, at different temperatures and bias voltages. The signal-to-noise ratio, spatial resolution, charge collection and overall efficiency have been measured.

متن کامل

Effect of hyperthermia before Neutron irradiation on chromosomal damages of human lymphocytes

Due to importance of combination therapies in cancer treatment, this study was performed to find the effects of hyperthermia and neutron irradiation and heir combination on the human lymphocytes. Blood samples were treated separately with 41.5 °C for 30 and 60 minutes, 43 °C for 15 and 30 minutes, as well as 10 cGy neutron irradiation. They also treated with hyperthermia followed by irradiation...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998