Development and validation of a computerized expert system for evaluation of automated visual fields from the Ischemic Optic Neuropathy Decompression Trial
نویسندگان
چکیده
BACKGROUND The objective of this report is to describe the methods used to develop and validate a computerized system to analyze Humphrey visual fields obtained from patients with non-arteritic anterior ischemic optic neuropathy (NAION) and enrolled in the Ischemic Optic Neuropathy Decompression Trial (IONDT). The IONDT was a multicenter study that included randomized and non-randomized patients with newly diagnosed NAION in the study eye. At baseline, randomized eyes had visual acuity of 20/64 or worse and non-randomized eyes had visual acuity of better than 20/64 or were associated with patients refusing randomization. Visual fields were measured before treatment using the Humphrey Field Analyzer with the 24-2 program, foveal threshold, and size III stimulus. METHODS We used visual fields from 189 non-IONDT eyes with NAION to develop the computerized classification system. Six neuro-ophthalmologists ("expert panel") described definitions for visual field patterns defects using 19 visual fields representing a range of pattern defect types. The expert panel then used 120 visual fields, classified using these definitions, to refine the rules, generating revised definitions for 13 visual field pattern defects and 3 levels of severity. These definitions were incorporated into a rule-based computerized classification system run on Excel(R) software. The computerized classification system was used to categorize visual field defects for an additional 95 NAION visual fields, and the expert panel was asked to independently classify the new fields and subsequently whether they agreed with the computer classification. To account for test variability over time, we derived an adjustment factor from the pooled short term fluctuation. We examined change in defects with and without adjustment in visual fields of study participants who demonstrated a visual acuity decrease within 30 days of NAION onset (progressive NAION). RESULTS Despite an agreed upon set of rules, there was not good agreement among the expert panel when their independent visual classifications were compared. A majority did concur with the computer classification for 91 of 95 visual fields. Remaining classification discrepancies could not be resolved without modifying existing definitions. Without using the adjustment factor, visual fields of 63.6% (14/22) patients with progressive NAION and no central defect, and all (7/7) patients with a paracentral defect, worsened within 30 days of NAION onset. After applying the adjustment factor, the visual fields of the same patients with no initial central defect and 5/7 of the patients with a paracentral defect were seen to worsen. CONCLUSION The IONDT developed a rule-based computerized system that consistently defines pattern and severity of visual fields of NAION patients for use in a research setting.
منابع مشابه
Computerized expert system for evaluation of automated visual fields from the Ischemic Optic Neuropathy Decompression Trial: methods, baseline fields, and six-month longitudinal follow-up.
PURPOSE To validate a computerized expert system evaluating visual fields in a prospective clinical trial, the Ischemic Optic Neuropathy Decompression Trial (IONDT). To identify the pattern and within-pattern severity of field defects for study eyes at baseline and 6-month follow-up. DESIGN Humphrey visual field (HVF) change was used as the outcome measure for a prospective, randomized, multi...
متن کاملRadial optic neurotomy as a treatment for anterior ischemic optic neuropathy secondary to optic disc drusen
IMPORTANCE Radial optic neurotomy (RON) was first described by Opremcak as a treatment for patients with central retinal vein occlusion (CRVO). The most common cause of visual loss in patients with optic disc drusen is nonarteritic anterior ischemic optic neuropathy (NAION). The pathogenesis of nonarteritic anterior ischemic optic neuropathy associated with optic disc drusen is assumed to be si...
متن کاملClinical profile of patients with nonarteritic anterior ischemic optic neuropathy presented to a referral center from 2003 to 2008.
BACKGROUND We conducted this study to report the demographics and clinical profile of patients with nonarteritic anterior ischemic optic neuropathy referred to a referral neuro-ophthalmology center in Iran. METHODS During a five-year period, 107 patients with nonarteritic anterior ischemic optic neuropathy were studied. A detailed history of previous or current systemic diseases was obtained ...
متن کاملDevelopment of a QFD-based expert system for CNC turning centre selection
Computer numerical control (CNC) machine tools are automated devices capable of generating complicated and intricate product shapes in shorter time. Selection of the best CNC machine tool is a critical, complex and time-consuming task due to availability of a wide range of alternatives and conflicting nature of several evaluation criteria. Although, the past researchers had attempted to select ...
متن کاملThe efficacy of optic nerve sheath decompression for anterior ischemic optic neuropathy and other optic neuropathies.
First proposed by De Wecker! in 1872 as a treatment for neuroretinitis, optic nerve sheath decompression (or fenestration) is an operation that has caused much controversy. This surgical therapy was not seriously considered until Davidson" and Smith, Hoyt, and Newton" reintroduced it in 1969 as an alternative therapy for chronic disk edema. Over the next 19 years, however, only about 60 cases o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- BMC Ophthalmology
دوره 6 شماره
صفحات -
تاریخ انتشار 2006