A sliding technique to load thin endothelial donor lamella onto Busin glide for Descemet-stripping automated endothelial keratoplasty
نویسندگان
چکیده
We describe a modified technique for loading donor corneal endothelial lamella onto a Busin glide(®) without causing wrinkles, as part of the procedure of Descemet-stripping automated endothelial keratoplasty. Briefly, after punching out a composite of the donor-endothelial lamella and a microkeratome-dissected cap, several drops of dispersive ophthalmic viscosurgical device are placed onto the endothelial surface. The Busin glide surface is then wetted with several drops of balanced salt solution. After the composite is transferred onto the Busin glide, hydrodissection of the potential space between the donor-endothelial lamella and the microkeratome-dissected cap is carefully performed to enable smooth detachment of these two lamellae. Whereas simply dragging the donor-endothelial lamella directly onto the glide can cause wrinkling or folding of the donor lamella, this technique enables smooth detachment of the composite without wrinkle or fold formation, and results in less endothelial cell damage.
منابع مشابه
A prospective study comparing EndoGlide and Busin glide insertion techniques in descemet stripping endothelial keratoplasty.
PURPOSE To compare a new insertion method using an EndoGlide (Angiotech/Network Medical Products) with the standard Busin glide (Moria USA) assisted insertion of the posterior lamellar corneal graft in Descemet stripping endothelial keratoplasty (DSEK). DESIGN Prospective, consecutive, comparative, nonrandomized study. METHODS Surgery was performed between October 2008 and October 2010 in 5...
متن کاملDescemet stripping automated endothelial keratoplasty using cultured corneal endothelial cells in a rabbit model.
OBJECTIVE To investigate the feasibility of Descemet stripping automated endothelial keratoplasty (DSAEK) using cultured human corneal endothelial cells (HCECs) in an animal model. METHODS Descemet stripping automated endothelial keratoplasty grafts were produced by seeding cultured HCEC suspensions onto human corneal stromal discs. Three insertion techniques were assessed in an ex vivo model...
متن کاملEndothelial keratoplasty with infant donor tissue
Here we report a case of endothelial keratoplasty with infant donor tissue obtained after brain death. A 52-year-old man with endothelial dysfunction of unknown cause in the right eye underwent non-Descemet stripping automated endothelial keratoplasty (nDSAEK) with tissue from an infant donor (2 years). Intraoperative and postoperative complications were recorded. Best corrected visual acuity a...
متن کاملEventual Endothelial Failure After Initial Corneal Clearing After a Detached Endothelial Graft in Fuchs Dystrophy
mated Bowman layer preparation with a 90to 100-mm-thick donor lamella of anterior stroma (instead of an 8to 12-mm-thick isolated Bowman layer graft). In our experience, the presence of donor stroma seems to degrade the optical quality of the transplanted cornea (as Descemet stripping endothelial keratoplasty/Descemet stripping automated endothelial keratoplasty grafts containing donor stroma ma...
متن کاملBanking of donor tissues for descemet stripping automated endothelial keratoplasty.
PURPOSE The demands for precut lamellar grafts for Descemet stripping automated endothelial keratoplasty rose in our eye bank from 74 in 2007 to 408 in 2010. To meet this expanding requirement, we explored the possibility to preserve these preparations in organ culture. METHODS Organ cultured corneas, stored in a medium containing 6% dextran, were mounted on a Moria artificial anterior chambe...
متن کامل