"Direct" and total bilirubin tests: contemporary problems.

نویسندگان

  • J A Lott
  • B T Doumas
چکیده

In eight unique challenges mailed by The College of American Pathologists Comprehensive Chemistry Survey to participating laboratories within 3 years, results for direct-reacting bilirubin (DBIL) were highly variable among the 12 largest peer groups, and most of the results differed greatly from the values obtained by a referred method. Peer-group mean values for total bilirubin (TBIL) were in much better agreement with each other and with those obtained by the Reference Method for TBIL. From a review of the information on the assay of DBIL provided to us by the manufacturers, we conclude that among the major causes of the large variability and bias in DBIL assays are problems with calibration, lack of a serum blank measurement, inadequate concentrations of HCl in the reaction mixture, inappropriate use of bichromatic correction methods, and possibly the use of wetting agents or surfactants in the reagent. Within-group SDs were small and generally acceptable. The among-peer-group variability in DBIL values is attributable to bias, not imprecision. We recommend several simple changes that could improve the accuracy of DBIL determinations in clinical laboratories.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Appraisal of Analytes in the Laboratory Panels for Liver Function Tests: Do we Need Aspartate Aminotransferase and Direct Bilirubin in the Panels? Running Head: AST and Direct Bilirubin in Lab Panels

Background: The Centers for Medicaid and Medicare Services approved a number of panels as screening tests including those for liver functions. The utility of routinely testing for Aspartate aminotransferase (AST) and direct bilirubin was questioned and empirical data analyzed to suggest alternatives. Methods: Tests done over six months were examined for AST, ALT, total and direct bilirubin valu...

متن کامل

آیا بیلی روبین می‌تواند شاخصی برای پیشگویی بیماری شریان کرونر باشد؟

Background and Aim: Oxidative interactions such as the formation of oxygen, peroxy radicals and LDL-cholesterol oxidation are involved in the development of atherosclerosis process This study aims to examine the relationship between serum bilirubin levels and the incidence of coronary artery disease. Materials and Methods: Eighty-five patients and ninety-two healthy volunteers were enrolled i...

متن کامل

Association of Sulfur Mustard-induced Ocular Problems with Serum and Blood Biochemical Parameters Changes

Background and objective:Many biochemical features of sulfur mustard (SM) intoxication remained unknown. So far, the direct association between biochemical parameter changes and ocular problems in patients exposed to SM is not evaluated.The current study aimed at evaluating the associations between the ocular findings in patients with SM intoxication and the changes of...

متن کامل

Significance of Mildly Elevated Liver Tests on Screening Biochemistry Profiles Significance of Mildly Elevated Liver Tests on Screening Biochemistry Profiles

The term "liver function tests" generally refers to a group of biochemical tests employed for the detection of liver and/or biliary tract disease.TM Although this term is somewhat of a misnomer, it is firmly entrenched in daily medical language and often referred to in its abbreviated form, "LFTs". Most automated chemistry batteries include the following liver tests: serum albumin, serum total ...

متن کامل

Does routine repeat testing of critical laboratory values improve their accuracy?

  Background: Routine repeat testing of critical laboratory values is very common these days to increase their accuracy and to avoid reporting false or infeasible results. We figure that repeat testing of critical laboratory values has any benefits or not.   Methods : We examined 2233 repeated critical laboratory values in 13 different hematology and chemistry tests including: hemoglobin, white...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 39 4  شماره 

صفحات  -

تاریخ انتشار 1993