Source of nonlinearity of the BOLD response revealed by simultaneous fMRI and NIRS

نویسندگان

  • Hiroshi Toyoda
  • Kenichi Kashikura
  • Tomohisa Okada
  • Satoru Nakashita
  • Manabu Honda
  • Yoshiharu Yonekura
  • Hideo Kawaguchi
  • Atsushi Maki
  • Norihiro Sadato
چکیده

The nonlinearity of the blood oxygenation level-dependent (BOLD) response to stimuli of different duration, particularly those of short duration, has been well studied by functional magnetic resonance imaging (fMRI). This nonlinearity is assumed to be due to neural adaptation and the nonlinearity of the response in the oxygen extraction fraction (OEF); the latter has not been examined quantitatively in humans. To evaluate how the OEF response contributes to the nonlinearity of the BOLD response to neural activity, we used simultaneous fMRI and near-infrared spectroscopy (NIRS). The responses to visual stimuli of four different durations were measured as changes in the BOLD signal and the NIRS-derived hemoglobin concentrations. The hemodynamic response nonlinearity was quantified using an impulse response function model with saturation nonlinearity scaling in the response amplitude, assuming that the unknown neural adaptation parameters varied within a physiologically feasible range. Independent of the degree of neural adaptation, the BOLD response consistently showed saturation nonlinearity similar to that of the OEF response estimated from the NIRS measures, the nonlinearity of which was greater than that of the response in the total hemoglobin concentration representing the cerebral blood volume (CBV). We also found that the contribution of the OEF response to the BOLD response was four to seven times greater than the contribution of the CBV response. Thus, we conclude that the nonlinearity of the BOLD response to neural activity originates mainly from that of the OEF response.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of CMRO2 and CBF using Simultaneous NIRS and fMRI

Introduction : We introduce an accurate technique to estimate the cerebral metabolic rate of oxygen (CMRO2) and cerebral blood flow (CBF) using simultaneously measured near infrared spectroscopy (NIRS) and blood oxygenation level dependent (BOLD) fMRI signals. Owing to simultaneous acquisition of both fMRI and NIRS, separate hypercapnia condition or arterial spin labeling (ASL) acquisition are ...

متن کامل

Effect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI

Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...

متن کامل

Evoked-cerebral blood oxygenation changes in false-negative activations in BOLD contrast functional MRI of patients with brain tumors.

Blood oxygenation level dependent contrast functional MRI (BOLD-fMRI) has been used to define the functional cortices of the brain in preoperative planning for tumor removal. However, some studies have demonstrated false-negative activations in such patients. We compared the evoked-cerebral blood oxygenation (CBO) changes measured by near-infrared spectroscopy (NIRS) and activation mapping of B...

متن کامل

Simultaneous quantitative assessment of cerebral physiology using respiratory-calibrated MRI and near-infrared spectroscopy in healthy adults

BACKGROUND Functional near-infrared spectroscopy (fNIRS) and functional MRI (fMRI) are non-invasive techniques used to relate activity in different brain regions to certain tasks. Respiratory calibration of the blood oxygen level dependent (BOLD) signal, and combined fNIRS-fMRI approaches have been used to quantify physiological subcomponents giving rise to the BOLD signal. A comparison of abso...

متن کامل

An fMRI study of human visual cortex in response to spatiotemporal properties of visual stimuli

  ABSTRACT  Background: The brain response to temporal frequencies (TF) has been already reported, but with no study reported for different TF with respect to various spatial frequencies (SF).  Materials and Methods: fMRI was performed by 1.5T GE-system in 14 volunteers during checkerboard, with TFs of 4, 6, 8 and 10Hz in low and high SFs of 0.5 and 8cpd.  Results: Average percentage BOLD signa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • NeuroImage

دوره 39 3  شماره 

صفحات  -

تاریخ انتشار 2008