Evaluation of a new method of irrigation and aspiration for removal of ophthalmic viscoelastic device during cataract surgery in a porcine model
نویسندگان
چکیده
BACKGROUND To determine if a method for irrigation and aspiration (I/A) during cataract surgery provides effective removal of ophthalmic viscoelastic device (OVD). METHODS Japanese porcine eyes were used to evaluate I/A performance with Technique 1 (the I/A tip placed on the center of the anterior surface of the IOL), Technique 2 (the I/A tip alternately pressed near the edge of the IOL optic anterior surface on one side and then the other to tilt the IOL back and forth), and Technique 3 (the I/A tip inserted behind the IOL optic, between it and the posterior capsule). Techniques 1 and 2 were compared using the Miyake-Apple posterior view video technique to visualize the flow of irrigation fluid containing triamcinolone acetonide particles behind the IOL. To check the efficacy of OVD removal from behind the IOL for of all three I/A techniques, OVD with fluorescein beads were inserted inside the lens capsule before implantation of the IOL. After each I/A technique, eyes were prepared for Miyake-Apple viewing and pictures of the lens capsule were taken using fluorescent microscopy. Residual fluorescein beads in the capsular bag were analyzed. RESULTS Technique 1 resulted in a straight flow of fluid behind the IOL, while Technique 2 resulted in a vortex flow. The average amount of OVD retained inside the capsule after using Technique 2 or 3 was significantly lower than after using Technique 1 (p <0.0001). CONCLUSIONS Technique 2 proved to remove more effectively fluorescein bead-labelled OVD under the IOL than Technique 1.
منابع مشابه
Comparative evaluation of post operative uveitis following use of viscoelastic (Methyl cellulose gel or healon) and air in patients C cataract surgery and lens implantation
Background: Cataract surgery lens implantation is the most common eye surgery that good quality of operation can help good visual outcome. One of the most common complication following cataract surgery is uveitis that usualy occur in first few weeks after operation. The aim of the present study was to compare the incidence of the post operative uveitis between viscoelastic substance and air in...
متن کاملHydro-visco-implantation Technique for Wound-assisted Foldable Intraocular Lens Implantation During Microincision Cataract Surgery
We have described a hydro-visco-implantation technique (simultaneous use of sodium hyaluronate and balanced salt solution) for wound-assisted intraocular lens (IOL) implantation and passive removal of ophthalmic viscosurgical device (OVD). In the technique, the capsular bag was filled approximately up to half with OVD, and anterior chamber was formed by bimanual irrigation cannula with continuo...
متن کاملChanges in corneal endothelium cell characteristics after cataract surgery with and without use of viscoelastic substances during intraocular lens implantation
PURPOSE To evaluate whether the use of balanced salt solution (BSS) or an ophthalmic viscoelastic device (OVD) during hydrophilic acrylic intraocular lens (IOL) implantation variously impacts corneal endothelial cell characteristics in eyes undergoing uneventful phacoemulsifications. METHODS Prospective nonrandomized observational clinical trial. Patients were assigned either to the BSS plus(...
متن کاملNeedle capsulorhexis in intumescent white cataract using slow injecting viscoelastic device through an anterior chamber maintainer.
The anterior capsulorhexis has got several intra and postoperative advantages over can opener or endocapsular capsulotomies and has become the standard capsulotomy technique for phacoemulsification (Zamini et al 2003, Neuhan TF 2004, Gimbel et al 1990). Anterior capsulorhexis can be performed using 26 G bent needle cystitome or Utratas forceps (Zamini et al 2003, Neuhan TF 2004). The needle cap...
متن کاملمقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کامل