Analytical conditions and separation performance of capillary chromatography based on the tube radial distribution of aqueous-organic mixture carrier solvents under laminar-flow conditions.
نویسندگان
چکیده
We have developed a capillary chromatography system using an open capillary tube made of fused-silica, polyethylene, or poly(tetrafluoroethylene), and a water-hydrophilic-hydrophobic organic mixture carrier solution. This tube radial distribution chromatography (TRDC) system works under laminar-flow conditions. In this study, the following analytical conditions in the TRDC system using a fused-silica capillary tube and a water-acetonitrile-ethyl acetate mixture carrier solution were for the first time examined: tube temperature, 5-25 degrees C; tube inner diameter, 50-250 microm; tube effective length, 100-200 cm; and flow rate, 0.2-1.5 microL min(-1). For example, the effects of temperature on the separation performance in the TRDC system were observed with an organic solvent-rich carrier solution; 1-naphthol and 2,6-naphthalenedisulfonic acid in a model mixture were eluted with baseline separation over the temperature range of 5-23 degrees C. The resolution, theoretical plate number, and height equivalent to the theoretical plate were calculated from the experimental data obtained by examining the effects of the tube length. A mixture of 1-naphthol, Eosin Y, 1-naphthalenesulfonic acid, 2,6-naphthalenedisulfonic acid, and 1,3,6-naphthalenetrisulfonic acid was subjected to the present TRDC system, and the analytes in the mixture solution were eluted in this order with the organic solvent-rich carrier solution, providing good separation performance on the chromatogram.
منابع مشابه
Experimental consideration of capillary chromatography based on tube radial distribution of ternary mixture carrier solvents under laminar flow conditions.
A capillary chromatography system has been developed based on the tube radial distribution of the carrier solvents using an open capillary tube and a water-acetonitrile-ethyl acetate mixture carrier solution. This tube radial distribution chromatography (TRDC) system works under laminar flow conditions. In this study, a phase diagram for the ternary mixture carrier solvents of water, acetonitri...
متن کاملFluidic Behavior of Polymer Compounds in an Open-Tubular Capillary with Ternary Mixed Carrier Solvents under Laminar Flow Conditions
An open-tubular capillary chromatography is developed based on tube radial distribution of the ternary mixed carrier solvents of water-hydrophilic/hydrophobic organic under laminar flow conditions. This is called “tube radial distribution chromatography” (TRDC). Fluidic behavior of the polymer compounds, FluoSpheres (1.0 m diameter), was examined by the TRDC system. The ternary mixture of wate...
متن کاملMicro-flow separation system using an open capillary tube that works under laminar flow conditions.
A micro-flow separation system was developed using an open capillary, fused-silica or polyethylene tube, and an aqueous-organic mixture (water-acetonitrile-ethyl acetate mixture) as a carrier solution. A model analyte solution containing 2,6-naphthalenedisulfonic acid and 1-naphthol was injected into the capillary tube by a gravity method. The analyte solution was subsequently delivered through...
متن کاملSeparation of optical isomers in capillary chromatography using a poly(tetrafluoroethylene) capillary tube and an aqueous-organic mixture carrier solution.
Capillary chromatography for the separation of optical isomers was developed using an untreated poly(tetrafluoroethylene) capillary tube and a water-hydrophilic/hydrophobic organic solvent mixture as a carrier solution. The open tubular capillary was 110 cm in length (90 cm effective length) and 100 microm in inner diameter. The carrier solution was prepared with a water-acetonitrile-ethyl acet...
متن کاملFundamental research and application of the specific fluidic behavior of mixed solvents in a microspace.
The author herein reviews a specific microfluidic behavior exhibited by mixed-solvent solutions in a microspace, coined as the tube radial distribution phenomenon (TRDP). The specific fluidic behavior was observed in the following solution systems: ternary water-hydrophilic/hydrophobic organic solvents, water-surfactant, water-ionic liquid, and fluorous/organic solvents. When the mixed homogene...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 26 7 شماره
صفحات -
تاریخ انتشار 2010