Feasibility of closed-loop titration of propofol and remifentanil guided by the spectral M-Entropy monitor.
نویسندگان
چکیده
BACKGROUND This randomized controlled trial describes automated coadministration of propofol and remifentanil, guided by M-Entropy analysis of the electroencephalogram. The authors tested the hypothesis that a novel dual-loop controller with an M-Entropy monitor increases time spent within predetermined target entropy ranges. METHODS Patients scheduled for elective surgery were randomly assigned in this single-blind study using a computer-generated list, to either dual-loop control using a proportional-integral-derivative controller or skilled manual control of propofol and remifentanil using target-controlled-infusion systems. In each group, propofol and remifentanil administration was titrated to a state entropy target of 50 and was subsequently targeted to values between 40 and 60. The primary outcome was the global score, which included the percentage of state entropy or response entropy in the range 40-60, the median absolute performance error and wobble. Data are presented as medians [interquartile range]. RESULTS Thirty patients assigned to the dual-loop group and 31 assigned to the manual group completed the study. The dual-loop controller was able to provide induction and maintenance for all patients. The Global Score of State Entropy was better maintained with dual-loop than manual control (25 [19-53] vs. 44 [25-110], P = 0.043), and state entropy was more frequently maintained in the range of 40-60 (80 [60-85] vs. 60 [35-82]%, P = 0.046). Propofol (4.1 [2.9-4.9] vs. 4.5 [3.4-6.3] mg · kg(-1) · h(-1)) and remifentanil (0.18 [0.13-0.24] vs. 0.19 [0.15-0.26] μg · kg(-1) · min(-1)) consumptions and the incidence of somatic side effects were similar. CONCLUSION Intraoperative automated control of hypnosis and analgesia guided by M-Entropy is clinically feasible and more precise than skilled manual control.
منابع مشابه
Feasibility of closed-loop titration of propofol and remifentanil guided by the bispectral monitor in pediatric and adolescent patients: a prospective randomized study.
BACKGROUND This study was designed to assess the feasibility of dual closed-loop titration of propofol and remifentanil guided solely by the Bispectral Index (BIS) monitor in pediatric and adolescent patients during anesthesia. METHODS Children undergoing elective surgery in this single-blind randomized study were allocated into the closed-loop (auto) or manual (manual) group. Primary outcome...
متن کاملTitration of propofol for anesthetic induction and maintenance guided by the bispectral index: closed-loop versus manual control: a prospective, randomized, multicenter study.
BACKGROUND This report describes a closed-loop titration of propofol target control infusion based on a proportional-differential algorithm guided by the Bispectral Index (BIS) allowing induction and maintenance of general anesthesia and compares this to manual propofol target control infusion. METHODS One hundred sixty-four patients scheduled to undergo elective minor or major surgery were p...
متن کاملFeasibility of closed-loop co-administration of propofol and remifentanil guided by the bispectral index in obese patients: a prospective cohort comparison.
BACKGROUND We used an automated bispectral index (BIS)-guided dual-loop controller to determine propofol and remifentanil requirements during general anaesthesia in obese and lean surgical patients. METHODS Obese patients, BMI>35 kg m(-2), and lean patients (<25 kg m(-2)) having laparoscopic procedures were prospectively evaluated in this multicentre single-blind study. The automated controll...
متن کاملDiagnosis of vertebral canal haematoma by myelography and spiral computer tomography in a patient with an implantable cardioverter-defibrillator contraindicating magnetic resonance imaging.
1 Aho AJ, Yli-Hankala A, Lyytikäinen L-P, Jäntti V. Facial muscle activity, Response Entropy, and State Entropy indices during noxious stimuli in propofol–nitrous oxide or propofol–nitrous oxide–remifentanil anaesthesia without neuromuscular block. Br J Anaesth 2009; 102: 227–33 2 Wheeler P, Hoffman WE, Baughman VL, Koenig H. Response entropy increases during painful stimulation. J Neurosurg An...
متن کاملClosed-Loop Control Better than Open-Loop Control of Profofol TCI Guided by BIS: A Randomized, Controlled, Multicenter Clinical Trial to Evaluate the CONCERT-CL Closed-Loop System
BACKGROUND The CONCERT-CL closed-loop infusion system designed by VERYARK Technology Co., Ltd. (Guangxi, China) is an innovation using TCI combined with closed-loop controlled intravenous anesthesia under the guide of BIS. In this study we performed a randomized, controlled, multicenter study to compare closed-loop control and open-loop control of propofol by using the CONCERT-CL closed-loop in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 116 2 شماره
صفحات -
تاریخ انتشار 2012