Acute performance of steroid-eluting screw-in leads for atrial free wall pacing.
نویسندگان
چکیده
The aim of this study was to clarify the acute performance of steroid-eluting screw-in leads in comparison with that of nonsteroid screw-in leads for atrial free wall pacing. In 114 cases (68 males, 46 females, average age 70 years) with atrial free wall pacing by screw-in leads, pacing thresholds and P-wave amplitudes were compared at the time of implantation and 1 week later between 68 cases of nonsteroid and 46 cases of steroid-eluting screw-in leads. No significant differences were seen between the 2 groups at implantation in either voltage or current thresholds measured at pulse widths of 0.1, 0.3, 0.6, 1.0, 2.0 ms, or P-wave amplitudes. Pulse width thresholds at outputs of 2.5 V and 5.0 V were significantly lower for steroid leads 1 week after implantation (2.5 V: 0.34+/-0.27 ms nonsteroid vs. 0.12+/-0.08 ms steroid, p<0.001; 5.0 V: 0.12+/-0.08 ms nonsteroid vs. 0.06+/-0.02 ms steroid, p<0.01). P-wave amplitudes after 1 week were significantly higher for steroid leads (2.6+/-0.7 mV nonsteroid vs 3.0+/-1.2 mV steroid, p<0.001). Threshold rise, including pacing failure, was observed in 15 (22%) of the non-steroid leads, but in only 1 (2%) of the steroid leads. In conclusion, steroid-eluting screw-in leads suppress the acute rise of pacing thresholds in the right atrial free wall and their acute performance is better than that of non-steroid leads. These results suggest that appropriate low-output atrial pacing is feasible immediately after implantation.
منابع مشابه
Direct comparison of steroid and non-steroid eluting small surface pacing leads: randomized, multicenter clinical trial.
BACKGROUND The aim of the study was to evaluate the efficacy and safety of small surface steroid-eluting atrial and ventricular pacing leads in comparison to non-steroid leads using remote monitoring system (Biotronik Home Monitoring®). METHODS In this randomized multicenter prospective trial, SIELLO T steroid-eluting ventricular leads (n = 42) were compared to BPPU T non-steroid leads (n = 4...
متن کاملEpicardial left ventricular leads via minimally invasive technique: a role of steroid eluting leads
BACKGROUND We retrospectively assessed two types of sutureless screw-in left ventricular (LV) leads (steroid eluting vs. non-steroid eluting) in cardiac resynchronization therapy (CRT) implantation with regards to their electrical performance. METHODS Between March 2008 and May 2014 an epicardial LV lead was implanted in 32 patients after failed transvenous LV lead placement using a left-side...
متن کاملEndocardial and epicardial steroid lead pacing in the neonatal and paediatric age group.
AIM To compare the performance of steroid eluting epicardial and endocardial leads in infants and children requiring permanent pacing. METHODS Evaluation of pacing and sensing characteristics, impedances, and longevity of 159 steroid eluting leads implanted in 95 children. Group A consisted of 24 children weighing less than 15 kg with 15 endocardial leads (five atrial, 10 ventricular) and 19 ...
متن کاملPacing therapy in children.
BACKGROUND The importance of ventricular pacing site in pediatric pacemaker therapy has gradually become recognized. We reviewed our experience with a left ventricular (LV)-prioritized pacing strategy. METHODS AND RESULTS: Between 2000 and 2012, 60 patients underwent 76 permanent pacemaker implantations. Eight of the 29 reoperations involved ventricular lead repositioning for pacing-induced ven...
متن کاملLong-term follow-up shows excellent transmural atrial lead performance in patients with complex congenital heart disease.
BACKGROUND Many patients with congenital heart disease require permanent pacing for rhythm management but cannot undergo transvenous lead placement. In others, epicardial scarring prohibits adequate sensing and pacing thresholds using epicardial leads. This study describes long-term lead performance using a transmural atrial (epicardial to endocardial) pacing approach in patients with congenita...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Japanese circulation journal
دوره 63 7 شماره
صفحات -
تاریخ انتشار 1999