Comparision between bed side testing of blood glucose by glucometer vs centralized testing in a tertiary care hospital.
نویسندگان
چکیده
BACKGROUND To determine the accuracy, turnaround time and cost effectiveness of bedside monitoring of blood glucose levels by non-laboratory health care workers and centralized testing of blood glucose by automated analyzer in a tertiary care hospital. METHODS The study was conducted in Section of Chemical Pathology, Department of Pathology and Microbiology and Section of Endocrinology Department of Medicine, Aga Khan University and Hospital Karachi, from April 2005 to March 2006. One hundred and ten patients were included in the study. The blood glucose levels were analyzed on glucometer (Precision Abbott) by finger stick, using Biosensor Technology. At the same time venous blood was obtained to analyze glucose in clinical laboratory on automated analyzer (SYNCHRON CX7) by glucose oxidase method. RESULTS We observed good correlation between bed side glucometer and laboratory automated analyzer for glucose values between 3.3 mmol/L (60 mg/dl) and 16.7 (300 mg/dl). A significant difference was observed for glucose values less than 3.3 mmol/L (p = 0.002) and glucose values more than 16.67 mmol/l (p = 0.049). Mean Turnaround time for glucometer and automated analyzer were 0.08 hours and 2.49 hours respectively. The cost of glucose testing with glucometer was 48.8% lower than centralized lab based testing. CONCLUSION Bedside glucometer testing, though less expensive does not have good accuracy in acutely ill patient with either very high or very low blood glucose levels.
منابع مشابه
بررسی ارزش گلوکومتری در تشخیص هیپوگلیسمی نوزادان
Background and purpose: Hypoglycemia is an important problem in newborns which requires early diagnosis and treatment. Laboratory testing of blood glucose level and glucometer readings are used to detect hypoglycemia but sometimes the results are given late. This study aimed at evaluating the accuracy of glucometer in detection of hypoglycemia in newborns at neonate intensive care unit (NICU), ...
متن کاملComparison of Point of Care (POC) Testing of Glucose by B Braun Glucometer and Hemocue Glucose 201+ Analyser Versus Centralised Testing in Neonatal Intensive Care Unit (NICU).
BACKGROUND Neonatal hypoglycemia is the most common carbohydrate metabolic disturbance seen in case of neonates and especially in preterm neonates. Accurate and rapid determination of hypoglycemia and its prompt treatment is of utmost importance to decrease morbidity and mortality of neonates. AIMS To estimate blood glucose in neonates and test the efficacy of HemoCue Glucose 201+ analyser an...
متن کاملمقایسه میزان همخوانی یافتههای سنجش قندخون با استفاده از گلوکومتر ON CALL و گلوکوکارد با روش آزمایشگاهی استاندارد
Background: Diabetes Mellitus (DM) is one the most common chronic disease, with many complications including renal failure, blindness and non traumatic amputation. Prevention of complications is possible through monitoring and control of blood glucose levels. Considering how easy home blood glucose monitoring is, we decided to evaluate the performance of two available glucometers for detection...
متن کاملA Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia
Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of ...
متن کاملEpidemiology and antifungal susceptibility of Candida species in a tertiary care hospital, Kolkata, India
Background and Purpose: The incidence of fungal infection as well as candidemia has increased significantly, contributing to morbidity and mortality in the developed countries. The alarming increase in infections with multidrug resistant bacteria is due to overuse of a broad spectrum antimicrobials, which leads to over growth of Candida spp.; thus, enhancing its opportunity to cause the disease...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of Ayub Medical College, Abbottabad : JAMC
دوره 19 3 شماره
صفحات -
تاریخ انتشار 2007