Robustness of late lumen loss in discriminating drug-eluting stents across variable observational and randomized trials.

نویسندگان

  • Laura Mauri
  • E John Orav
  • Susana C Candia
  • Donald E Cutlip
  • Richard E Kuntz
چکیده

BACKGROUND Binary angiographic and clinical restenosis rates can vary widely between clinical studies, even for the same stent, influenced heavily by case-mix covariates that differ among observational and randomized trials intended to assess a given stent system. We hypothesized that mean in-stent late loss might be a more stable estimator of restenosis propensity across such studies. METHODS AND RESULTS In 46 trials of drug-eluting and bare-metal stenting, increasing mean late loss was associated with higher target lesion revascularization (TLR) rates (P<0.001). When the class of bare-metal stents was compared with the class of effective drug-eluting stents, late loss was more discriminating than TLR as measured by the high intraclass correlation coefficient (rho) (late loss, rho=0.71 versus TLR, rho=0.22; 95% CI of difference=0.33, 0.65). When the individual drug-eluting stents and bare-metal stents were compared, late loss was a better discriminator than TLR (0.68 versus 0.19; 95% CI of difference=0.24, 0.60). Greater adjustments of study covariates are needed to stabilize assessments of TLR compared with late loss because of greater influence of reference vessel diameter on TLR than on in-stent late loss. Optimization of late loss with the use of a novel method of standardization according to diabetes prevalence and mean lesion length resulted in minor adjustments in late loss (<0.08 mm for 90% of reported trials) and an ordered array of mean late loss values for the stent systems studied. CONCLUSIONS Late loss is more reliable than restenosis rates for discriminating restenosis propensity between new drug-eluting stent platforms across studies and might be the optimum end point for evaluating drug-eluting stents in early, nonrandomized studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Letter regarding article by Mauri et al, "Late loss in lumen diameter and binary restenosis for drug-eluting stent comparison".

BACKGROUND Published rates of coronary restenosis have fallen below 10% in drug-eluting stent trials. Early evaluations of new stents have used continuous end points that are presumed surrogates for restenosis, but the generalizability and power of such end points have not been examined systematically. METHODS AND RESULTS We examined the relationship between incremental changes in observed la...

متن کامل

Late Loss in Lumen Diameter and Binary Restenosis for Drug-Eluting Stent Comparison

Background—Published rates of coronary restenosis have fallen below 10% in drug-eluting stent trials. Early evaluations of new stents have used continuous end points that are presumed surrogates for restenosis, but the generalizability and power of such end points have not been examined systematically. Methods and Results—We examined the relationship between incremental changes in observed late...

متن کامل

Low Resolution Limits and Inaccurate Algorithms Decrease Significantly the Value of Late Loss in Current Drug-Eluting Stent Trials

Quantitative coronary and vascular angiography (QCA resp., QVA) remains the current gold standard for evaluation of restenosis. Late loss as one of the most commonly accepted parameters to highlight efficacy of the various devices has shown high correlation to clinical parameters but, surprisingly, has no impact on the evaluation of the remaining amount of restenostic tissue. The current clinic...

متن کامل

Polymer-free sirolimus-eluting versus polymer-based paclitaxel-eluting stents: an individual patient data analysis of randomized trials.

INTRODUCTION AND OBJECTIVES The angiographic and clinical efficacy of polymer-free sirolimus-eluting stents vs polymer-based paclitaxel-eluting stents remain a matter of debate. We sought to investigate angiographic and clinical measures of efficacy of polymer-free sirolimus-eluting stents vs polymer-based paclitaxel-eluting stents. METHODS Patient data from the randomized intracoronary stent...

متن کامل

Clinical performance of biodegradable versus permanent polymer drug-eluting stents: A meta-analysis of randomized clinical trials at long-term follow-up

Several types of biodegradable polymer drug-eluting stents (BPDES) have been used for percutaneous transluminal angioplasty; however, the safety and efficiency of these BPDES have not been fully evaluated. A meta-analysis was, therefore, conducted to compare the clinical performance of BPDES with that of permanent polymer drug-eluting stents (PPDES) in unselected patients with coronary stenosis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 112 18  شماره 

صفحات  -

تاریخ انتشار 2005