GlideScope Video Laryngoscope for Difficult Intubation in Emergency Patients: a Quasi-Randomized Controlled Trial.
نویسندگان
چکیده
Macintosh direct laryngoscope has been the most widely used device for tracheal intubation. GlideScope video laryngoscope (GVL) has been recently introduced as an alternative device for performing intubation; however, its validity in emergency settings has not been thoroughly evaluated. The aim of this study was to compare Macintosh direct laryngoscope versus GVL for emergency endotracheal intubation. This quasi-randomized clinical trial was performed on 97 patients referred to Imam Reza Hospital whom all needed emergency intubation in 2011. Patients were divided into two groups of the easy airway and difficult airway; intubation was performed for patients with direct laryngoscopy or GVL. Then, the patients were evaluated in terms of demographic characteristics, successful intubation rate and intubation time. Data was analyzed by SPSS software 16. There was no significant difference in demographic characteristics of the patients in both easy airway and difficult airway groups who intubated with direct laryngoscopy and GVL methods (P>0.05). In difficult airway group, a significant difference was found in successful intubation at the first attempt (60.9% vs. 87.5%; P=0.036), overall intubation time (32.7 ± 14.58 vs. 22.5±7.88; P<0.001) and first attempt intubation time (28.43 ± 12.51 vs. 21.48±7.8; P=0.001) between direct laryngoscopy and GVL. These variables were not significantly different between two methods in easy airway group. According to the results, GVL can be a useful alternative to direct laryngoscopy in emergency situations and especially in cases with a difficult airway.
منابع مشابه
Comparison of the Incidence of Sore Throat and Hemodynamic Changes in Airway Management by Macintosh, Glideoscope Laryngoscope and Laryngeal Mask Airway Techniques: Randomized Controlled Trial
Background: Studies have shown that postoperative sore throat is the most common complication of tracheal intubation, However, the actual incidence and extent of it are not well documented. Objective: The aim of this study was to evaluate and compare the incidence of sore throat and hemodynamic Changes in Macintosh, Glidescope Laryngoscope and laryngeal mask airway techniques in elective surg...
متن کاملمقایسه میزان موفقیت لوله گذاری تراشه بعد از آموزش با دو روش گلایدسکوپ و لارنگوسکوپ
Background: Tracheal intubation is one of the most essential skills employed by all healthcare providers, nevertheless novice intubators turn out to be less successful when they initially perform the intubation. Video- laryngoscopes (GlideScopes) are novel instruments able to increase the success rate of tracheal intubation training. The aim of this study was to compare the success rate of trac...
متن کاملComparing GlideScope Video Laryngoscope and Macintosh Laryngoscope Regarding Hemodynamic Responses During Orotracheal Intubation: A Randomized Controlled Trial
BACKGROUND To determine if the GlideScope® videolaryngoscope (GVL) could attenuate the hemodynamic responses to orotracheal intubation compared with conventional Macintosh laryngoscope. OBJECTIVES The aim of this relatively large randomized trial was to compare the hemodynamic stress responses during laryngoscopy and tracheal intubation using GVL versus MCL amongst healthy adult individuals r...
متن کاملComparison of the Glidescope® and Pentax AWS® laryngoscopes to the Macintosh laryngoscope for use by Advanced Paramedics in easy and simulated difficult intubation
BACKGROUND Intubation of the trachea in the pre-hospital setting may be lifesaving in severely ill and injured patients. However, tracheal intubation is frequently difficult to perform in this challenging environment, is associated with a lower success rate, and failed tracheal intubation constitutes an important cause of morbidity. Novel indirect laryngoscopes, such as the Glidescope and the A...
متن کاملMethods to Improve Success With the GlideScope Video Laryngoscope.
Occasionally intubation of patients is difficult using a video laryngoscope (GlideScope, Verathon Medical) because of an inability to guide the endotracheal tube to the glottis or pass the tube into the trachea despite an adequate view of the glottis. We examined methods to improve success when this difficulty occurs. A literature search revealed 253 potential sources, with 25 meeting search cr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta medica Iranica
دوره 53 12 شماره
صفحات -
تاریخ انتشار 2015