Open versus endoscopic bone resection of the dorsolateral calcaneal edge: a cadaveric analysis comparing three dimensional CT scans

نویسندگان

  • Klaus Edgar Roth
  • Ramona Mueller
  • Eike Schwand
  • Gerrit Stefen Maier
  • Irene Schmidtmann
  • Murat Sariyar
  • Uwe Maus
چکیده

BACKGROUND It has been claimed that endoscopic calcaneoplasty offers some advantages over open techniques in the surgical treatment of Haglund's deformity due to reduced postoperative complications like stiffness and pain. Bony over-resection places patients at risk of these complications. The resulting question with regard to the quantitative differences of the extent of the bone removed using these two techniques has not yet been answered. The purpose of the study was to determine the resection volume of calcaneal bone for open and endoscopic surgical techniques. METHODS 16 feet obtained from body donors were operated on in equal parts using either open surgical or endoscopic techniques, with the technique selected on a random basis. High-resolution CT scans were obtained before and after the interventional procedure and analysed to obtain 3-D polygon models. Post-operative models were subtracted from pre-operative models to provide the volume change resulting from the intervention. This was then correlated with the bone mineral density (BMD) of the preparation. RESULTS The extent of bony resection was greater in open surgical techniques than in endoscopic approaches. The average volume of bone resection was 0.80 (±0.34) cm(3) in the endoscopic group and 3.04 (±2.91) cm(3) in the group that underwent open surgery. After adjustment for bone mineral density the extent of the resection was significantly larger (p = 0.018) in the group undergoing open surgery. The two groups did not differ significantly with regard to BMD (p > 0.1). The extent of the resection fell by 0.011 cm(3) per 1 mg/cm(3) areal bone mineral density, i.e., a slightly lower degree of bone resection was associated with a higher bone mineral density. CONCLUSIONS Assuming that the resection volume was adequate to treat the patient's complaints a smaller resection volume seen in our study using an endoscopic technique might lead to fewer postoperative complaints and faster recovery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inter-observer agreement between 2-dimensional CT versus 3-dimensional I-Space model in the Diagnosis of Occult Scaphoid Fractures

  Background: The I-Space is a radiological imaging system in which Computed Tomography (CT)-scans can be evaluated as a three dimensional hologram. The aim of this study is to analyze the value of virtual reality (I-Space) in diagnosing acute occult scaphoid fractures.   Methods: A convenient cohort of 24 patients with a CT-scan from prior studies, without a scaphoid fracture on radiograph, ye...

متن کامل

Standard edge detection algorithms versus conventional auto-contouring used for a three-dimensional rigid CT-CT matching

Background: To reduce uncertainties of patient positioning, the Computerized Tomography (CT) images acquired at the treatment planning time can be compared with those images obtained during radiation dose delivery. This can be followed during dose delivery procedure as Image Guided radiotherapy (IGRT) to verify the prescribed radiation dose delivery to the target as well as to monitor ...

متن کامل

Cadaveric Study of the Junction Point Where the Gastrocnemius Aponeurosis Joins the Soleus Aponeurosis

Purpose To study the location of the junction point where the gastrocnemius aponeurosis joins the soleus aponeurosis to form the Achilles tendon. Methods Twelve lower limb specimens were used. The distance between the medial tibial plateau and the superior border of the posterior calcaneal tubercle (A) was measured and the distances of the junction point to the superior border of the posterio...

متن کامل

Value of 3D Reconstructions of CT Scans for Calcaneal Fracture Assessment.

BACKGROUND The interpretation of CT scans for the evaluation of calcaneal fractures is difficult. Three-dimensional (3D) reconstruction (volume rendering technique [VRT]) has been valuable in the evaluation of irregularly shaped bones. However, their value for the analysis of calcaneal fractures is still debated. Therefore, the objective of this study was to assess the effect of additional use ...

متن کامل

In vitro Evaluation of the Relationship between Gray Scales in Digital Intraoral Radiographs and Hounsfield Units in CT Scans

Background: Jaw bone quality plays an essential role in treatment planning and prognosis of dental implants. Regarding several available methods for bone density measurements, they are not routinely used before implant surgery due to hard accessibility.Objective: An in vitro investigation of correlation between average gray scale in direct digital radiographs and Hounsfield units in CT-Scan pro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2014