in Vitro Study of the Pulp Chamber Temperature Rise during Light-activated Bleaching

نویسندگان

  • Thaise Graciele Carrasco
  • Laise Daniela Carrasco-Guerisoli
  • Izabel Cristina Fröner
چکیده

This study evaluated in vitro the pulp chamber temperature rise induced by the light-activated dental bleaching technique using different light sources. The root portions of 78 extracted sound human mandibular incisors were sectioned approximately 2 mm below the cementoenamel junction. The root cavities of the crowns were enlarged to facilitate the correct placing of the sensor into the pulp chamber. Half of specimens (n=39) was assigned to receive a 35% hydrogen peroxide gel on the buccal surface and the other halt (n=39) not to receive the bleaching agent. Three groups (n=13) were formed for each condition (bleach or no bleach) according to the use of 3 light sources recommended for dental bleaching: a light-emitting diode (LED)laser system, a LED unit and a conventional halogen light. The light sources were positioned perpendicular to the buccal surface at a distance of 5 mm and activated during 30 s. The differences between the initial and the highest temperature readings for each specimen were obtained, and, from the temperature changes, the means for each specimen and each group were calculated. The values of temperature rise were compared using Kruskal-Wallis test at 1% significance level. Temperature rise varied significantly depending on the light-curing unit, with statistically significant differences (p<0.01) among the groups. When the bleaching agent was not applied, the halogen light induced the highest temperature rise (2.38+/-0.66 degrees C). The LED unit produced the lowest temperature increase (0.29+/-0.13 degrees C); but there was no significant difference between LED unit and LED-laser system (0.35+/-0.15 degrees C) (p>0.01). When the bleaching agent was applied, there were significant differences among groups (p<0.01): halogen light induced the highest temperature rise (1.41+/-0.64 degrees C), and LED-laser system the lowest (0.33+/-0.12 degrees C); however, there was no difference between LED-laser system and LED unit (0.44+/-0.11 degrees C). LED and LED-laser system did not differ significantly from each other regardless the temperature rise occurred with or without bleaching agent application. It may be concluded that during light-activated tooth bleaching, with or without the bleaching agent, halogen light promoted higher pulp chamber temperature rise than LED unit and LED-laser system. The tested light-curing units provided increases in the pulp chamber temperature that were compatible with pulpal health.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of an in-office bleaching system (ZOOM) on pulp chamber temperature in vitro.

AIM Several new techniques and materials for in-office bleaching have been introduced recently. The aim of this in vitro study was to measure the temperature increase in the pulp chamber of extracted teeth produced by the Zoom! in-office bleaching system and to investigate the influence of this light in conjunction with the bleaching gel on pulp temperature rise. METHODS AND MATERIALS Ten ext...

متن کامل

Effect of diode laser and light-emitting diode (LED) activated bleaching with 35% hydrogen peroxide on microleakage of class-V composite restorations: An in vitro study

Introduction: Residual oxygen-free radicals of bleaching agents before composite restorations can increase microleakage in enamel and dentin margins, and also various bleaching techniques are being developed using light sources. The present study was conducted to compare the effect of diode laser bleaching and LED activated bleaching on the microleakage of composite restorations. Materials & M...

متن کامل

A study of temperature rise in the pulp chamber during composite polymerization with different light-curing units.

AIM The study compared pulp temperature rise during polymerization of resin-based composites (RBCs) using halogen and LED light-curing units (LCUs). METHODS AND MATERIALS A total of 32 teeth extracted from patients aged 11-18 years were used in the study. Thermocouples placed on the roof of the pulp chamber using a novel 'split-tooth' method. In Group 1 a halogen LCU with a light intensity of...

متن کامل

Temperature changes under demineralized dentin during polymerization of three resin-based restorative materials using QTH and LED units

OBJECTIVES Light-curing of resin-based materials (RBMs) increases the pulp chamber temperature, with detrimental effects on the vital pulp. This in vitro study compared the temperature rise under demineralized human tooth dentin during light-curing and the degrees of conversion (DCs) of three different RBMs using quartz tungsten halogen (QTH) and light-emitting diode (LED) units (LCUs). MATER...

متن کامل

In-vitro assessment of temperature rise in the pulp during orthodontic bonding.

INTRODUCTION In this in-vitro study, we evaluated the temperature changes in the pulp chamber during bracket bonding using 4 different light sources. METHODS Eighty intact extracted maxillary central incisors were used. The teeth were divided into 4 groups of 20 teeth each. Brackets (Mini Twin, Dentaurum, Ispringen, Germany) were bonded with Transbond XT (3M Unitek, Monrovia, Calif) adhesive ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2008