Use of Different Methods of Intramedullary Nailing for Fixation of Distal Radius Fractures: A Retrospective Analysis of Clinical and Radiological Outcomes
نویسندگان
چکیده
BACKGROUND We aimed to evaluate the clinical and radiologic outcomes of using Sonoma WRx versus Micronail intramedullary nailing for the fixation of distal radius fractures. MATERIAL AND METHODS A total of 68 patients with primarily extra-articular and simple intra-articular fractures of the distal radius who underwent intramedullary distal radius fixation using Sonoma WRx (n=39) or Micronail (n=29) intramedullary nails were enrolled in the study. The clinical outcome measures included the range of motion (ROM), visual analog scale (VAS), functional outcomes (patient-reported Disabilities of the Arm, Shoulder and Hand [DASH] score and clinician-based Gartland-Werley score), radiographic scores (Stewart score), and parameters related to the quality of radiographic reduction and complications (radial inclination, volar tilt, radial height, and radio-ulnar variance). RESULTS Significantly higher DASH (15.0±3.3 vs. 8.3±1.5, p<0.001) and Gartland-Werley (4.9±5.4 vs. 2.9±4.2, p=0.029) scores, longer scopy time (21.0±3.9 min vs. 15.8±2.5 min, p<0.001), lower ROM for wrist extension (69.5±4.4° vs. 77.1±7.6°, p<0.001), higher ROM for wrist supination (81.9±5.1° vs. 78.7±3.1°, p<0.001), and higher complications rates (37.9% vs. 15.4%, p=0.034) were noted in the Micronail group compared to those in the Sonoma WRx group. CONCLUSIONS Our findings revealed that Sonoma WRx and Micronail implants were equally effective and useful minimally invasive options for treating distal radius fractures. Further, we consider Sonoma WRx superior in terms of shorter operative time, lower complication rates, and better functional outcome scores.
منابع مشابه
Use of Volar Locking Plate Versus Intramedullary Nailing for Fixation of Distal Radius Fractures: A Retrospective Analysis of Clinical and Radiographic Outcomes
BACKGROUND The objective of this study was to evaluate clinical and radiographic outcomes of volar plate versus intramedullary nailing for fixation of distal radius fractures. MATERIAL AND METHODS This retrospective study included 64 patients with extra-articular and simple intra-articular fractures of the distal radius who underwent intramedullary fixation using volar locking plate (n=35, mean...
متن کاملThe use of combined 3.5 LCP unicortical plate and nail fixation in proximal tibia fractures and prevention of valgus and anterior angulation
Introduction: Intramedullary nailing (IMN) of high tibia fracture has some mechanical and biological advantages over the other form of fixation. However, valgus, apex anterior malalignment and anterior displacement of proximal fragment commonly occur after isolated IMN fixation of proximal high tibia fracture. The purpose of this study is to determine the effectiveness of using 3.5-mm locking c...
متن کاملمقایسه اکسترنال فیکساتور با اینتـرامدولاری نیلینگ در درمان شکستگیهای باز تیبیا
Background and purpose: Ëxternal fixation is currently considered as a standard treatment for open tibial fractures however, due to the long-term hospitalization and some other complications, some researchers have proposed intramedullary nailing as the alternative surgical treatment. This study was conducted to compare the treatment of open tibial shaft fractures by external fixation and int...
متن کاملنتایج درمان شکستگی تنه هومروس به روش میلهگذاری اینترمدولاری
Background & Aim: Most acute humeral shaft fractures can be successfully treated by conservative methods. Operation is recommended for certain fractures. Intramedullary nailing offers a dependable solution for the treatment of humeral shaft fractures, especially in polytrauma patients. The aim of this study was to evaluate intramedullary nailing outcomes and complications in humeral fractur...
متن کاملClinical Outcomes of Intramedullary and Extramedullary Fixation in Unstable Intertrochanteric Fractures: A Randomized Clinical Trial
Background: The best method for repairing intertrochanteric fractures is still controversial. The fixation methods includeextramedullary (EM) and intramedullary (IM). Studies that compare IM and EM fixations for unstable hip fractures arerare. In this study, our goal was to compare the efficacy of EM and IM fixation in treatment of unstable intertrochantericfractures.Met...
متن کامل