Pseudo-no-Reflow Phenomenon in Carotid Artery Stenting using FilterWire EX: Successful Recovery by Aspiration Thrombectomy

نویسندگان

  • Seung Hwan Han
  • Woong Chol Kang
  • Tae Hoon Ahn
  • Eak Kyun Shin
چکیده

Distal protection devices such as FilterWire EX have been widely used in carotid artery stenting, however, the large amount of atherothrombotic debris entrapped in the filter could reduce or stop antegrade flow. We present a case of pseudo-no-reflow phenomenon after postdilatation of the stent in a patient with asymptomatic carotid artery stenosis. After several passes using an Export Aspiration catheter, normal flow in the internal carotid artery was restored. Aspiration thrombectomy can successfully recover pseudo-no-reflow phenomenon.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Flow Impairment during Carotid Artery Stenting Using Two Types of Eccentric Filter Embolic Protection Devices

We investigated the angiographic findings and the clinical outcomes after carotid artery stenting (CAS) using two different, eccentric filter embolic protection devices (EPDs). Between July 2010 and August 2015, 175 CAS procedures were performed using a self-expandable closed-cell stent and a simple eccentric filter EPD (FilterWire EZ in 86 and Spider FX in 89 procedures). The angiographic find...

متن کامل

Plaque gruel of atheromatous coronary lesion may contribute to the no-reflow phenomenon in patients with acute coronary syndrome.

BACKGROUND No-reflow associated with direct angioplasty (PCI) of patients with acute coronary syndromes (ACS) is associated with unfavorable results. METHODS AND RESULTS We used a new thrombectomy device to treat 51 lesions in 48 consecutive ACS patients (40 male and 8 female; mean age 63 years) and conducted a microscopic analysis of aspirates and blood samples retrieved from the culprit cor...

متن کامل

ANGIOPLASTY AND STENTING OF CAROTID ARTERY STENOSIS WITH EMBOLIC PROTECTION DEVICES

Background: Carotid artery stenting (CAS) has recently been recommended as an alternative to carotid endarterectomy (CEA) by some clinicians. Objective: This study was designed to evaluate the success rate and in-hospital and 30-day adverse events in our first experiences in Iran for CAS with protection devices, to document our results and guide further use of CAS. Methods: From December 2...

متن کامل

Adjuvant Tirofiban Injection Through Deployed Solitaire Stent As a Rescue Technique After failed Mechanical Thrombectomy in Acute Stroke

PURPOSE We present our experiences of intra-arterial tirofiban injection through a deployed Solitaire stent as a rescue therapy after failed mechanical thrombectomy in patients with acute ischemic stroke. MATERIALS AND METHODS Data on 18 patients treated with adjunctive tirofiban injection through a temporarily deployed Solitaire stent after failed mechanical thrombectomy were retrospectively...

متن کامل

Distal Protection During Primary Percutaneous Coronary Intervention for ST-elevation Myocardial Infarction

Primary percutaneous coronary intervention (PCI) is the standard treatment strategy for patients with ST-elevation myocardial infarction (STEMI). However, despite the early restoration of epicardial artery flow, microvascular obstruction and reduced myocardial perfusion may occur. The " no-reflow " phenomenon is associated with a large infarct size and poor outcomes. The pathogenesis of no-refl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 24  شماره 

صفحات  -

تاریخ انتشار 2009