Magnetic resonance imaging with an optical atomic magnetometer.
نویسندگان
چکیده
We report an approach for the detection of magnetic resonance imaging without superconducting magnets and cryogenics: optical atomic magnetometry. This technique possesses a high sensitivity independent of the strength of the static magnetic field, extending the applicability of magnetic resonance imaging to low magnetic fields and eliminating imaging artifacts associated with high fields. By coupling with a remote-detection scheme, thereby improving the filling factor of the sample, we obtained time-resolved flow images of water with a temporal resolution of 0.1 s and spatial resolutions of 1.6 mm perpendicular to the flow and 4.5 mm along the flow. Potentially inexpensive, compact, and mobile, our technique provides a viable alternative for MRI detection with substantially enhanced sensitivity and time resolution for various situations where traditional MRI is not optimal.
منابع مشابه
All-optical magnetometry for NMR detection in a micro-Tesla field and unshielded environment.
An all-optical atomic magnetometer is used to detect a proton free-precession signal from a water sample polarized in a 0.7 T field and remotely analyzed in a 4 microT field. Nuclear spins are manipulated either by pi/2 pulses or by non-adiabatic rotation. The magnetometer operates at room temperature, in an unshielded environment and has a dual-channel sensor for differential measurements.
متن کاملCharacterizing and imaging magnetic nanoparticles by optical magnetometry
We review our ongoing work on deploying optical (atomic) magnetometry for measuring the magnetic response of magnetic nanoparticle (MNP) samples, yielding MNP size distributions, and other sample parameters like Néel relaxation time τ , saturation magnetisation Ms, anisotropy constant K and magnetic susceptibility χ. We address magnetorelaxation (MRX) signals, in which the decaying magnetisatio...
متن کاملNMR detection with an atomic magnetometer.
We demonstrate detection of NMR signals using a noncryogenic atomic magnetometer and describe several novel applications of this technique. A nuclear spin-precession signal from water is detected using a spin-exchange-relaxation-free potassium magnetometer. We also demonstrate detection of less than 10(13) 129Xe atoms whose NMR signal is enhanced by a factor of 540 due to Fermi-contact interact...
متن کاملDetection of radio frequency magnetic fields using nonlinear magneto - optical rotation
We describe a room-temperature alkali-metal atomic magnetometer for detection of small, high frequency magnetic fields. The magnetometer operates by detecting optical rotation due to the precession of an aligned ground state in the presence of a small oscillating magnetic field. The resonance frequency of the magnetometer can be adjusted to any desired value by tuning the bias magnetic field. W...
متن کاملDevelopment of an Advanced Optical Coherence Tomography System for Radiation Dosimetry
Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Proceedings of the National Academy of Sciences of the United States of America
دوره 103 34 شماره
صفحات -
تاریخ انتشار 2006