Adsorption of (99m)Tc-radiopharmaceuticals onto injection vials and syringes.

نویسندگان

  • Ahmad Mushtaq
  • Taj Ur Rehman
  • Muhammad Safdar Mansur
  • Mustanser Jehangir
چکیده

UNLABELLED Many groups have reported the adsorption or retention of (99m)Tc-radiopharmaceuticals on injection vials and disposable plastic syringes. Such an enormously high loss of radioactivity would result in poor images, radiation exposure, waste, and economic burdens. We therefore decided to investigate the extent of adsorption or retention of several (99m)Tc-radiopharmaceuticals on injection vials, rubber stoppers, and plastic syringes. These radiopharmaceuticals are produced as lyophilized kits in our department and supplied to various hospitals practicing nuclear medicine in Pakistan. METHODS A vial containing lyophilized material was reconstituted with 3 mL of freshly eluted Na(99m)TcO(4). A 1-mL aliquot of the resulting solution was withdrawn into a syringe at 0.25, 0.5, 1, 3, and 5 h after preparation. All preparations were stored at room temperature ( approximately 22 degrees C). After each withdrawal, the vial was reweighed and the activity remaining in the vial was measured using a radioisotope calibrator. The sample was reinjected into the vial. From the original weight and activity of solution in the vial, the initial activity per gram was calculated. From the weight and activity remaining in the vial after withdrawal of the sample, the activity per gram of the sample was calculated. From the difference between the initial activity per gram and the activity per gram of the sample, the percentage of (99m)Tc adsorbed on the vial was calculated. All preparations were kept in the syringe for 15 min, and the activity was measured before and after the syringe was emptied. The needle and plunger of the syringe were separated, and activity in the needle and plunger was also measured. RESULTS The labeling efficiency of all radiopharmaceuticals used during these studies was more than 95%. In most cases, the activity of (99m)Tc found on the rubber stopper was less than 1%. Adsorption of (99m)Tc onto vials increased gradually with storage time. Adsorption was minimal at the initial stages, whereas maximum retention was noted after 5 h. Nearly 5% adsorption of activity was observed after 5 h of storage time on vials of sestamibi, mercaptoacetyltriglycine, dextran, ciprofloxacin, and dimercaptosuccinic acid (III and V). Retention of activity on needles ranged from 1% to 2% for all preparations studied. Plungers did not show any significant retention of radioactivity; in most cases, retention was less than 0.5%. The maximum retention of radioactivity on plastic syringe bodies was more than 3% for sestamibi, dimercaptosuccinic acid, dextran, pyrophosphate, and phytate. CONCLUSION The results revealed that losses of radioactivity from (99m)Tc-radiopharmaceuticals in these objects (glass vial, rubber stopper, plastic syringes, plungers, and needles) are not alarming in our setup.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adsorption of some technetium-99m radiopharmaceuticals onto disposable plastic syringes.

OBJECTIVE The purpose of this study was to determine the adsorption behavior of some widely used, commercially available 99mTc radiopharmaceuticals onto different types of plastic syringes. METHODS Kits were reconstituted with 99mTc-pertechnetate diluted with 0.9% saline to produce maximum radioactive concentrations, as stated by the manufacturers. Aliquots of the solutions were transferred t...

متن کامل

Adsorption of 99mTc-sestamibi onto plastic syringes: evaluation of factors affecting the degree of adsorption and their impact on clinical studies.

UNLABELLED The purpose of this study was to document the extent of adhesion of (99m)Tc-sestamibi to syringes in patient procedures, determine factors that influence the degree of adhesion, and evaluate alternatives to our current practice that would either result in a more reproducible degree of adhesion or, ideally, eliminate adhesion. METHODS The extent of adhesion was documented in 216 pat...

متن کامل

Dose from syringe procedures during technetium-99m radiopharmaceutical preparation.

UNLABELLED We examined the dose from 99mTc contained in syringes and shielded vials to assess in detail the dose burdens in a central pharmacy. METHODS Absorbed-dose rates at the end of the plunger of a shielded syringe, when 99mTc is contained either in the syringe or in a shielded vial from which the activity would be drawn, were measured with CaF2 dosimeters. The dose rates also were calcu...

متن کامل

NUCLEAR PHARMACY Dose from Syringe Procedures During Technetium-99m Radiopharmaceutical Preparation

We examined the dose from mTc contained in syringes and shielded vials to assess in detail the dose burdens in a central pharmacy. Methods: Absorbed-dose rates at the end of the plunger of a shielded syringe, when mTc is contained either in the syringe or in a shielded vial from which the activity would be drawn, were measured with CaF2 dosimeters. The dose rates also were calculated with a Mon...

متن کامل

Quantitative and Qualitative Scintigraphic Measurement of Renal Function in Persian Cat Using 99mTechnetium Ethylenedicysteine and 99mTechnetium Diethylenetriaminepentaacetic

Objective- To consider the use of renal scintigraphic evaluation of kidney function in Persian cat and make a comparison between 99mTechnetium ethylenedicysteine and 99mTechnetium diethylenetriaminepentaacetic in renal scintigraphy. Design- Descriptive study Animals- 6 male healthy adult Persian cats - no clinical sign of renal disorders and prior to presentation. Proce...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 36 2  شماره 

صفحات  -

تاریخ انتشار 2008