Determination of Full Energy Peak Efficiency of NaI(Tl) Detector Depending on Efficiency Transfer Principle for Conversion Form Experimental Values

نویسندگان

  • Mohamed Abd-Elzaher
  • Mohamed Salem Badawi
  • Ahmed El-Khatib
  • Abouzeid Ahmed Thabet
چکیده

In this work we calibrated the NaI(Tl) scintillation detectors (5.08 × 5.08 cm and 7.62 × 7.62 cm) and the Full Energy Peak Efficiency (FEPE) for these detectors have been calculated for point sources placed at different positions on the detector axis using the analytical approach of the effective solid angle ratio. This approach is based on the direct mathematical method reported by Selim and Abbas [1,2] and has been used successfully before to calibrate the cylindrical, parallelepiped, and 4π NaI(Tl) detectors by using point, plane and volumetric sources. In addition, the present method is free of some major inconveniences of the conventional methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo Determination of Full Energy Peak Efficiency for HPGe Detector and Self-Absorption Correction of Environmental Samples

The Monte Carlo method was used to determine full energy efficiency of a high-purity germanium (HPGe) coaxial detector within an energy range of 53.2-2614 keV. Also, measurement was carried out for a standard Marinelli beaker of 600cm3, which was placed into the reference material of mixed gamma. The plot of the experimentally derived effic...

متن کامل

Dedicated Monte Carlo Procedures Applied in Gamma- ray Spectrometry Used in Decommissioning of Nuclear Facilities

Because the experimental efficiency calibration is limited to several measurement geometries and cannot be applied directly to all measurement configurations, the efficiency transfer method for the efficiency computation was applied using ETNA software. An approach using efficiencies measured with point sources combined with theoretical procedures was applied for obtaining the peak efficiency ε...

متن کامل

Determination of the flux of a neutron radioisotope source through gold activation method

Introduction: In recent years, the use of neutrons has increased in various fields such as medicine and industry. One of the important applications of neutrons is in medical research. Neutrons have greater linear energy transfer than gamma rays and are considered more dangerous radiation. Hence, the detection and determination of neutron dose is a very important and vital issu...

متن کامل

Determination of marine gamma activity and study of the minimum detectable activity (MDA) in 4pi geometry based on Monte Carlo simulation.

Monte Carlo simulations were performed using the GEANT4 code for the investigation of gamma-ray absorption in water in different spherical geometries and of the efficiency of a NaI(Tl) detector for different radionuclides in the aquatic environment. In order to test the reliability of these simulations, experimental values of the NaI(Tl) detector efficiency were deduced and seem to be in good a...

متن کامل

Photon dosimetry based on selective data sampling for the NaI(TL) detector

Radiation detection is essential for determining of radiation dose. Depend on the detector and dosimetry method, detection process is performed in different levels. Pulse counting is the first level of detection. Typically, the output of a radiation detector for determining value of the radiation dose cannot be used directly. Through changing the response function or the readout detector, is tr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013