Methodological aspects of Staphylococcus aureus peptidoglycan serology: comparisons between solid-phase radioimmunoassay and enzyme-linked immunosorbent assay.

نویسندگان

  • B Christensson
  • F Espersen
  • S A Hedström
  • G Kronvall
چکیده

In the present studies we compared the ability of two commonly used assays, solid-phase radioimmunoassay and enzyme-linked immunosorbent assay (ELISA), to detect human antibodies to Staphylococcus aureus peptidoglycan. ELISA was superior, with a reproducibility of 12.0%, as compared with 18.1% in solid-phase radioimmunoassay. Much lower serum dilutions could be used in ELISA. We also studied the effects of solubilizing the antigen by lysostaphin, lysozyme, or ultrasonication. Lysostaphin-treated peptidoglycan cannot be recommended since solid-phase radioimmunoassay could not distinguish positive from negative serum samples with this preparation. On the other hand, the sensitivity in both assays was high when peptidoglycan treated with lysozyme for 240 min or with ultrasonication for 30 min was used as antigen. The interassay correlation between solid-phase radioimmunoassay and ELISA was slightly better with sonicated peptidoglycan (correlation coefficient = 0.94, P less than 0.01), as compared with lysozyme-treated peptidoglycan (correlation coefficient = 0.76, P less than 0.01). We recommend the ELISA with sonicated peptidoglycan as antigen for use in routine serology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DEVELOPMENT OF A SIMPLE AND SENSITIVE ENZYME- LINKED IMMUNOSORBENT ASSAY (ELISA) FOR CLINICAL MEASUREMENT OF TESTOSTERONE USING PENICILLINASE AS LABEL

An enzyme-linked immunosorbent assay using a homologous combination of antiserum raised against testosterone-3-0-carboxymethyloxime-bovine serum albumin (T-3-0-CMO-BSA ) and penicillinase-labelled T-3-0-CMO was developed. This assay was utilized to measure testosterone in serum samples of male and female subjects. The sensitivity of the assay is 50pg/well and the antibody developed crossrea...

متن کامل

Antibody response to teichoic acid and peptidoglycan in Staphylococcus aureus osteomyelitis.

An enzyme-linked immunosorbent assay was used to evaluate the immunoglobulin G (IgG) response to Staphylococcus aureus crude teichoic acid (TA) and peptidoglycan (PG) in both rabbits and patients with osteomyelitis. In rabbits with experimental S. aureus osteomyelitis, elevated levels of IgG to TA were present in 13/18 (72%) of the serum samples obtained at 4 and 10 weeks postinfection. In cont...

متن کامل

Detection of hepatitis A virus and antibody by solid-phase radioimmunoassay and enzyme-linked immunosorbent assay with monoclonal antibodies.

Monoclonal antibodies (K3-2F2 and K3-4C8) raised against hepatitis A virus were used to develop a solid-phase radioimmunoassay and enzyme-linked immunosorbent assay for the detection of hepatitis A virus and antibody. Assays with this pair of monoclonal antibodies were compared in parallel with similarly constructed solid-phase radioimmunoassays and enzyme-linked immunosorbent assays in which h...

متن کامل

Enzyme-Linked Immunosorbent Assay of Progesterone in Serum Using Penicillinase as Label

An enzyme-linked immunosorbent assay (ELISA) for progesterone measurement in serum or plasma samples using penicillinase as label enzyme is reported. A C3 and C11 derivatives of progesterone were prepared and conjugated to bovin serum albumin (BSA). Polyclonal antibody against these two immunogens were prepared in New Zealand white rabbits. Purified Ig fractions of antibodies were immobilized o...

متن کامل

Antibody responses in patients with staphylococcal septicemia against two Staphylococcus aureus fibrinogen binding proteins: clumping factor and an extracellular fibrinogen binding protein.

We analyzed the serum antibody responses against two Staphylococcus aureus fibrinogen binding proteins, the cell-bound clumping factor (Clf) and an extracellular fibrinogen binding protein (Efb). The material consisted of 105 consecutive serum samples from 41 patients suffering from S. aureus septicemia and 72 serum samples from healthy individuals. An enzyme-linked immunosorbent assay (ELISA) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 19 5  شماره 

صفحات  -

تاریخ انتشار 1984