A New Method for Fetal Electrocardiogram Denoising Using Blind Source Separation and Empirical Mode Decomposition
نویسندگان
چکیده
1 “Politehnica” University of Bucharest, Applied Electronics and Information Engineering Department, E-mail: [email protected], rodica. [email protected]. 2 “Carol Davila” University of Medicine and Pharmacy, Obstretics and Gynecology Department, Bucharest, Romania, E-mail: ilinca. [email protected]. A NEW METHOD FOR FETAL ELECTROCARDIOGRAM DENOISING USING BLIND SOURCE SEPARATION AND EMPIRICAL MODE DECOMPOSITION
منابع مشابه
Blind Voice Separation Based on Empirical Mode Decomposition and Grey Wolf Optimizer Algorithm
Blind voice separation refers to retrieve a set of independent sources combined by an unknown destructive system. The proposed separation procedure is based on processing of the observed sources without having any information about the combinational model or statistics of the source signals. Also, the number of combined sources is usually predefined and it is difficult to estimate based on the ...
متن کاملA New Algorithm for Fetal QRS Detection in Abdominal Recordings
The acquisition and the analysis of electrophysiological signals are often followed by the detection of parameters of clinical importance. In the case of fetal electrocardiogram signal, the presence of QRS complex is the best indicator of the fetal heart rate, as it is directly correlated with the fetal cardiac activity. However, to detect this complex, it is necessary to separate the signal fr...
متن کاملA Fault Diagnosis Method for Automaton based on Morphological Component Analysis and Ensemble Empirical Mode Decomposition
In the fault diagnosis of automaton, the vibration signal presents non-stationary and non-periodic, which make it difficult to extract the fault features. To solve this problem, an automaton fault diagnosis method based on morphological component analysis (MCA) and ensemble empirical mode decomposition (EEMD) was proposed. Based on the advantages of the morphological component analysis method i...
متن کاملFetal ECG Extraction by Combining Single-Channel SVD and Cyclostationarity-Based Blind Source Separation
Fetal Electrocardiogram (FECG) can provide important clinical information for the assessment of fetal well-being. However, the extraction of FECG from the maternal abdominal wall remains an open problem due to various kinds of interferences and noises, where the maternal Electrocardiogram (MECG) is the dominant source of interference. In this study, a novel FECG extraction framework by combinin...
متن کاملEEG Artifact Removal System for Depression Using a Hybrid Denoising Approach
Introduction: Clinicians use several computer-aided diagnostic systems for depression to authorize their diagnosis. An electroencephalogram (EEG) may be used as an objective tool for early diagnosis of depression and controlling it from reaching a severe and permanent state. However, artifact contamination reduces the accuracy in EEG signal processing systems. Methods: This work proposes a no...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -