A laboratory model to evaluate cutout resistance of implants for pertrochanteric fracture fixation.
نویسندگان
چکیده
OBJECTIVES To establish a laboratory model of implant cutout, which can evaluate the effect of implant design on cutout resistance in a clinically realistic "worst case" scenario. SETTING Orthopaedic biomechanics laboratory. DESIGN Implant cutout was simulated in an unstable pertrochanteric fracture model, which accounted for dynamic loading, osteoporotic bone, and a defined implant offset. For model characterization, lag screw cutout was simulated in human cadaveric specimens and in polyurethane foam surrogates. Subsequently, foam surrogates were used to determine differences in cutout resistance between 2 common lag screws (dynamic hip screw, Gamma) and 2 novel blade-type implant designs (dynamic helical hip system, trochanteric fixation nail). MAIN OUTCOME MEASURES Implant migration was continuously recorded with a spatial motion tracking system as a function of the applied loading cycles. In addition, the total number of loading cycles to cutout failure was determined for specific load amplitudes. RESULTS Implant migration in polyurethane surrogates closely correlated with that in cadaveric specimens, but yielded higher reproducibility and consistent cutout failure. The cutout model was able to delineate significant differences in cutout resistance between specific implant designs. At any of 4 load amplitudes (0.8 kN, 1.0 kN, 1.2 kN, 1.4 kN) dynamic hip screw lag screws failed earliest. The gamma nail lag screw could sustain significantly more loading cycles than the dynamic hip screw. Of all implants, trochanteric fixation nail implants demonstrated the highest cutout resistance. CONCLUSIONS Implant design can significantly affect the fixation strength and cutout resistance of implants for pertrochanteric fracture fixation. The novel cutout model can predict differences in cutout resistance between distinct implant designs.
منابع مشابه
Lag screws for hip fracture fixation: Evaluation of migration resistance under simulated walking.
Previous mechanical studies concerning cut-out of lag screws for pertrochanteric hip fractures have relied on static or dynamic uniaxial loading regimens to induce construct failure by varus collapse and superior cut-out. However, the hip is loaded in a multiplanar, dynamic manner during normal gait. We designed a hip implant performance simulator (HIPS) system to evaluate lag screw cut-out und...
متن کاملEarly outcomes of proximal humerus fracture fixation with locking plate and intramedullary fibular strut graft.
Proximal humerus fractures are commonly encountered in elderly patients. Surgical treatment demonstrates high complication rates, including varus construct collapse and screw cutout. In this study, the authors evaluate the clinical outcome of locking plate fixation with intramedullary fibular strut graft augmentation as a primary surgical treatment in the prevention of early collapse and screw ...
متن کاملConditions affecting treatment of pertrochanteric osteomyelitis.
BACKGROUND Although osteomyelitis following treatment of pertrochanteric fractures is rare, management can be difficult and often results in several physical and economic difficulties. Data regarding treatment of patients with pertrochanteric osteomyelitis is currently limited. This retrospective study evaluates the management of pertrochanteric osteomyelitis and presents our experience using a...
متن کاملComplications After Hip Nailing for Fractures.
Pertrochanteric fractures in elderly patients represent a major health issue. The available surgical options are fixation with extramedullary devices, intramedullary nailing, and arthroplasty. Intramedullary nailing for hip fractures has become more popular in recent years. Advantages of intramedullary nailing for hip fracture fixation include a more efficient load transfer due to the proximity...
متن کاملIs Distal Fixation Necessary in Cephalomedullary Fixation of Pertrochanteric Femur Fractures? Factors Associated with Blade Cut-Out
Volume 16 June 2015 37 Is Distal Fixation Necessary in Cephalomedullary Fixation of Pertrochanteric Femur Fractures? Factors Associated with Blade Cut-Out Dan Tobert, MD1 Steve Huffaker, MD, PhD1 Mitchel B. Harris, MD1
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of orthopaedic trauma
دوره 19 6 شماره
صفحات -
تاریخ انتشار 2004