An under-occluded roller pump is less hemolytic than a centrifugal pump.
نویسندگان
چکیده
The purpose of this study is to measure and compare the hemolysis produced by roller pumps with varied occlusion settings and a centrifugal pump. The null hypothesis is that there is no difference in the Index of Hemolysis (IH = gm Hb/100 L pumped) produced by a roller pump (RP) at four different occlusion settings and a centrifugal pump (CP) at the same blood flow rate (4.5 L/min) and afterload (250 mmHg, +/-10 mmHg) over three hours. Five identical closed-loop circuits were assembled and primed with saline. The pumps were then calibrated and occlusions were set. In three circuits, the occlusion for the RP was opened at 5 RPMs to support 150, 225, or 300 mmHg (+/-10 mmHg) against a clamped line. In one circuit, a RP was adjusted to a barely non-occlusive setting (1 cm drop/30 inch gradient). The fifth circuit employed a CP. Prior to testing, the saline in each circuit was replaced with one liter of fresh bovine blood (Hct = 22 +/- 2%). The IH for each treatment was compared in six trials yielding a statistical power > 0.80. Analysis of variance with multiple comparison (p < or = 0.05) demonstrated that compared to the barely non-occlusive setting, the IH in the centrifugal pump was not significantly greater. Under-occluded RP settings yielded IHs significantly less than the CP. It appears that opening the occlusion on a roller pump allows a lower IH compared to traditional RP occlusion setting or centrifugal pumping.
منابع مشابه
Significant safety advantages gained with an improved pressure-regulated blood pump.
A prototype of a non-occlusive pressure-regulated blood pump (M-pump) was evaluated in-vitro for safety in a comparative study with the roller and centrifugal pumps. The M-pump consists of collapsible tubing of unique design wrapped under tension around a rotor without a stator. The prototype M-pumps were tested in vitro to evaluate performance with respect to flow/ pressure characteristics, he...
متن کاملNon-occlusive condition with the Better-Header roller pump: impacts of flow dynamics and hemolysis.
PURPOSE Impacts on hemolysis and backflow using a non-occlusive setting with the Better-Header (BH) roller pump were investigated. METHODS AND RESULTS Pump flow of a non-occlusion setting was measured with a pump speed of 3 L/min and 5 L/min against various after-loads. With the non-occlusive setting (BH-NO350), backflow was less than 10% if the pump pressure head was <300 mmHg. When the outl...
متن کاملAn Experimental Investigation into the Effects of High Viscosity and Foamy Oil Rheology on a Centrifugal Pump Performance
This paper presents the effect of high viscosity oil and two-phase foamy-oil flow on the performance of a single stage centrifugal pump. As a part of this, the applicability of a pipe viscometer to determine the foamy oil viscosity is investigated. Unlike previous studies, a sealed fluid tank is used in a closed flow loop to allow conditioning the two-phase mixture to create foamy-oil. Furtherm...
متن کاملNumerical Study of the tongue geometry effects on the cavitation and performance of a centrifugal pump in off-design conditions
In this study, the effects of the volute tongue geometry variation on the head, efficiency, velocity distribution and cavitation structure of a centrifugal pump in the steady flow behavior under off-design conditions have been investigated. Numerical simulation modeling based on the turbulence model with a hybrid grid is used to simulate the flow within the modeled pump. The flow is simulated ...
متن کاملProinflammatory mediator response in coronary bypass surgery using a centrifugal or a roller pump.
Major surgery, trauma, and infection induce a proinflammatory mediator response which, if excessive, may cause tissue injury. The response was measured during elective coronary bypass surgery when a centrifugal pump or a roller pump, differing in their basic working principles, was used for extracorporeal circulation (ECC). Eight patients were perfused with a centrifugal pump and eight patients...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of extra-corporeal technology
دوره 29 1 شماره
صفحات -
تاریخ انتشار 1997