Effect of Spherical Aberration on the Optical Quality after Implantation of Two Different Aspherical Intraocular Lenses
نویسندگان
چکیده
PURPOSE To compare the effect of spherical aberration on optical quality in eyes with two different aspherical intraocular lenses. METHODS 120 eyes of 60 patients underwent phacoemulsification. In patients' eyes, an aberration-free IOL (Aspira-aA; Human Optics) or an aberration-correcting aspherical IOL (Tecnis ZCB00; Abott Medical Optics) was randomly implanted. After surgery, contrast sensitivity and wavefront measurements as well as tilt and decentration measurements were performed. RESULTS Contrast sensitivity was significantly higher in eyes with Aspira lens under mesopic conditions with 12 cycles per degree (CPD) and under photopic conditions with 18 CPD (p = 0.02). Wavefront measurements showed a higher total spherical aberration with a minimal pupil size of 4 mm in the Aspira group (0.05 ± 0.03) than in the Tecnis group (0.03 ± 0.02) (p = 0.001). Strehl ratio was higher in eyes with Tecnis (0.28 ± 0.17) with a minimal pupil size larger than 5 mm than that with Aspira (0.16 ± 0.14) (p = 0.04). In pupils with a minimum diameter of 4 mm spherical aberration had a significant effect on Strehl ratio, but not in pupils with a diameter less than 4 mm. CONCLUSIONS Optical quality was better in eyes with the aberration-correcting Tecnis IOL when pupils were large. In contrast, this could not be shown in eyes with pupils under 4 mm or larger. This trial is registered with Clinicaltrials.gov NCT03224728.
منابع مشابه
Evaluation of actual retinal images produced by misaligned aspheric intraocular lenses in a model eye
PURPOSE To examine the effect of misalignment (decentration and tilt) of intraocular lenses (IOLs) on retinal image quality using a water-immersed model eye with corneal spherical aberration adjusted to the values found in normal human eyes (spherical aberration 0.25 μm; pupil diameter 6 mm). METHODS Three types of IOL holders were prepared. The first was without decentration or tilt, the sec...
متن کاملQuality of vision after cataract surgery after Tecnis Z9000 intraocular lens implantation: effect of contrast sensitivity and wavefront aberration improvements on the quality of daily vision.
PURPOSE To compare ocular performance and quality of vision in pseudophakic eyes with an aspherical intraocular lens (IOL) or a conventional spherical IOL. SETTING Bretonneau University Hospital, Tours, France. METHODS Twenty patients (40 eyes) were randomly divided in 2 equal groups to bilaterally receive the aspherical Tecnis Z9000 IOL (AMO) or the spherical CeeOn Edge 911 IOL (AMO). Cont...
متن کاملComparing the effect of two different intraocular lenses on optical aberrations in bilaterally operated eyes for cataract
OBJECTIVE To assess high order and spherical aberrations results of hydrophobic acrylic AMO Sensar AR40E and hydrophobic acrylic Alcon AcrySof SA60AT intraocular lenses after implantation in cases with bilateral cataract. METHODS Cases diagnosed as bilateral cataract were included in the study and preoperative aberration measurements were recorded by using Nidek OPD SCAN-ARK 1000. Groups were...
متن کاملHigher order aberration comparison between two aspherical intraocular lenses: MC6125AS and Akreos advanced optics.
AIM To compare higher order aberrations in two aspherical intraocular lenses (IOLs): Akreos advanced optics (AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface (MC6125AS) with each other. METHODS Forty eyes of 39 patients underwent phacoemulsification and Akreos AO and MC6125AS were implanted in their eyes in a random manner. Three months post-operatively, higher order aberra...
متن کاملEffect of decentration of wavefront-corrected intraocular lenses on the higher-order aberrations of the eye.
OBJECTIVE To evaluate the theoretical effect of decentration of aspherical intraocular lenses (IOLs) and wavefront-corrected IOLs up to the sixth order on higher-order aberrations (HOAs) (third through sixth order) of the eye. METHODS An aspherical IOL with HOAs of fourth-order spherical aberrations only (-0.287 microm with a 6-mm pupil) and a wavefront-corrected IOL with HOAs of equal magnit...