A balloon tipped catheter for obtaining his bundle electrograms without fluoroscopy.

نویسندگان

  • S G Meister
  • V S Banka
  • K D Chadda
  • R H Helfant
چکیده

A technique for recording His bundle activity in man without fluoroscopic guidance is described. Balloon tipped triOr tetrapolar catheters were designed with pacing electrodes located at the catheter tip, and two fine sensing electrodes 4 and 5 cm behind it. The catheter tip was preformed into a "J" curve. Following percutaneous transfemoral insertion, the catheter is floated to the right ventricle under electrocardiographic control. This tip configuration and the transfemoral route of insertioni typically directs the catheter into an inverted "J" position with its tip in or near the right ventricular apex. Subsequent catheter withdrawal carries the sensing electrodes through the superior portion of the tricuspid valve and permits recording from the His bundle. With this technique His bundle recordings were possible in 23 of 24 patients. Re-advancement into the right ventricular apex permits stable temporary pacing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Balloon Tipped Catheter for Obtaining His Bundle Electrograms Without

A technique for recording His bundle activity in man without fluoroscopic guidance is described. Balloon tipped triOr tetrapolar catheters were designed with pacing electrodes located at the catheter tip, and two fine sensing electrodes 4 and 5 cm behind it. The catheter tip was preformed into a "J" curve. Following percutaneous transfemoral insertion, the catheter is floated to the right ventr...

متن کامل

Use of balloon-tipped catheters in the critically ill child.

A retrospective study of our experience in the placement of 19 consecutive balloon-tipped catheters in the pulmonary artery of 18 children disclosed that the procedure can be performed with relative ease in the intensive care unit without the aid of fluoroscopy. Insertion of the catheters was not associated with any serious complications. Catheter malfunction, however, occurred in 9 of 18 patie...

متن کامل

Feasibility of real-time magnetic resonance imaging for catheter guidance in electrophysiology studies.

BACKGROUND Compared with fluoroscopy, the current imaging standard of care for guidance of electrophysiology procedures, magnetic resonance imaging (MRI) provides improved soft-tissue resolution and eliminates radiation exposure. However, because of inherent magnetic forces and electromagnetic interference, the MRI environment poses challenges for electrophysiology procedures. In this study, we...

متن کامل

The effect of electrode configuration on the unipolar His-bundle electrogram.

Although "unipolar electrograms" recorded from the His-bundle position have been used to help position catheters for His-bundle ablation, the techniques used to record such electrograms have not been standardized. The effects of five anode locations (right chest wall, anterior chest wall, left chest wall, posterior chest wall, and inferior vena cava) on unipolar atrial, His bundle and ventricul...

متن کامل

Mapping and ablation of ventricular tachycardia guided by virtual electrograms using a noncontact, computerized mapping system.

OBJECTIVES The purpose of this study was to describe a computerized mapping system that utilizes a noncontact, 64 electrode balloon catheter to compute virtual electrograms simultaneously at 3,360 left ventricular (LV) sites and to assess the clinical utility of this system for mapping and ablating ventricular tachycardia (VT). BACKGROUND Mapping VT in the electrophysiology laboratory convent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 49 1  شماره 

صفحات  -

تاریخ انتشار 1974