Scattering Data versus Lens Data on Surfaces
نویسندگان
چکیده
The scattering data of a Riemannian manifold with boundary record the incoming and outgoing directions of each geodesic passing through. We show that the scattering data of a generic Riemannian surface with no trapped geodesics and no conjugate points determine the lengths of geodesics. Counterexamples exists when trapped geodesics are allowed.
منابع مشابه
Lens Rigidity with Trapped Geodesics in Two Dimensions
We consider the scattering and lens rigidity of compact surfaces with boundary that have a trapped geodesic. In particular we show that the flat cylinder and the flat Möbius strip are determined by their lens data. We also see by example that the flat Möbius strip is not determined by it’s scattering data. We then consider the case of negatively curved cylinders with convex boundary and show th...
متن کاملDevelopment of a human eye model incorporated with intraocular scattering for visual performance assessment.
A biometry-based human eye model was developed by using the empirical anatomic and optical data of ocular parameters. The gradient refractive index of the crystalline lens was modeled by concentric conicoid isoindical surfaces and was adaptive to accommodation and age. The chromatic dispersion of ocular media was described by Cauchy equations. The intraocular scattering model was composed of vo...
متن کاملDepth-dependent forward light scattering by donor lenses.
PURPOSE To determine quantitatively forward light scattering in the human lens as a function of depth. To use this to explain the psychophysical result, verified earlier in vitro, showing total light scattering in the human lens to decrease with scattering angle according to an approximate power law (power -2). METHODS The amount of light scattered by donor lenses (n = 15; age range, 43 to 82...
متن کاملاثرات سایه مشخصه سطوح در پدیده پراکندگی از سطوح ناهموار
In the wave scattering from rough surfaces investigated by using the surface morphology and the vertical AFM, in general the correct and complete results cannot be obtained. If the roughness with respect to the wavelength is more than a critical limit, the theoretical calculation is not the same as the experimental data, and this inequality cannot be corrected without considering the shadowing...
متن کامل3 year simvastatin treatment and lens nuclear back scattering.
AIM To determine if 3 year treatment of hypercholesterolaemia with simvastatin causes an increase of lens nuclear back scattering. METHODS 160 patients with hypercholesterolaemia in the Scandinavian Simvastatin Survival Study (4S) were followed for 3 years. Half (80) of the patients took simvastatin and half (80) received placebo. The lens was photographed with a Topcon SL-45 slit lamp camera...
متن کامل