Comparison of open and percutaneous lumbar pedicle screw revision rate using 3-D image guidance and intraoperative CT.
نویسندگان
چکیده
Complications arising from a malpositioned screw can be both devastating and costly. The incidence of neurologic injury secondary to a malpositioned screw is reported to be as high as 7% to 12%. The advancement of image-guided technology has allowed surgeons to place screws more accurately and confirm correct placement prior to leaving the operating room. Only a small number of studies have examined image-guided pedicle screw accuracy in terms of intraoperative revision and reoperation rates. The purpose of this study was to determine the intraoperative revision and return to surgery rates for navigated lumbar pedicle screws and to compare navigated open and percutaneous techniques. The authors reviewed 199 cases of 3-dimensional image-guided lumbar pedicle screw instrumentation from November 2006 to December 2011. Screw or K-wire removal, repositioning, or eventual abandonment of insertion were noted. Chi-square test was used to determine statistical significance in rates between the 2 groups (alpha=0.05). The authors also noted return to surgery secondary to complications from a malpositioned screw. The overall intraoperative revision rate of navigated lumbar pedicle screws was 4.6%. There were significantly more revisions in the percutaneously inserted screws (7.5%) than with the open technique (2.7%) (P=.0004). If K-wire revisions are excluded, there was no statistically significant difference in intraoperative revision rates between the percutaneous and open groups (2.1% vs 2.7%, respectively) (P=.0004). No patients underwent reoperation for a malpositioned screw. This technology has virtually eliminated the need for reoperation for screw malposition. It may suggest a more cost-effective way of preventing neurovascular injuries and revision surgeries.
منابع مشابه
The surgical learning curve and accuracy of minimally invasive lumbar pedicle screw placement using CT based computer-assisted navigation plus continuous electromyography monitoring – a retrospective review of 627 screws in 150 patients
OBJECTIVE This study retrospectively assessed the accuracy of placement of lumbar pedicle screws placed by a single surgeon using a minimally-invasive, intra-operative CT-based computer navigated technique in combination with continuous electromyography (EMG) monitoring. The rates of incorrectly positioned screws were reviewed in the context of the surgeon's experience and learning curve. MET...
متن کاملElectromagnetic Navigation in Minimally Invasive Spine Surgery: Results of a Cadaveric Study to Evaluate Percutaneous Pedicle Screw Insertion
BACKGROUND This cadaveric study compared efficacy and safety of an electromagnetic (EM) guidance system versus conventional fluoroscopy for percutaneous pedicle screw fixation. As percutaneous pedicle screw fixation becomes increasingly common in spinal surgery, intraoperative imaging systems that maximize efficiency while minimizing radiation exposure and inaccurate trajectories will be progre...
متن کاملTracked ultrasound snapshots in percutaneous pedicle screw placement navigation: a feasibility study.
BACKGROUND Computerized navigation improves the accuracy of minimally invasive pedicle screw placement during spine surgery. Such navigation, however, exposes both the patient and the staff to radiation during surgery. To avoid intraoperative exposure to radiation, tracked ultrasound snapshots-ultrasound image frames coupled with corresponding spatial positions-could be used to map preoperative...
متن کاملComputed tomography-based navigation-assisted pedicle screw insertion for thoracic and lumbar spine fractures.
BACKGROUND Incorrect placement of pedicle screws may lead to neurovascular injury, so the position is important for the reduction of spinal fractures. CT-based image-guided surgery has been promoted as a means to theoretically improve the accuracy of pedicle screw placement. Patients who underwent CT-based navigation-assisted pedicle screw fixation for thoracic or lumbar fractures were reviewed...
متن کاملFirst experience with laser guided percutaneous pedicle screw placement in the lumbar spine
Since many years surgeons are trying to optimize pedicle screw placement in spine surgeries to reduce severe complications. Intraoperative image guidance could improve the accuracy in pedicle screw placement (Tain 2011). However no significant reduction of complications could be seen (Verma 2010). With the implementation of robotic 3D flat-panel detectors in hybrid operating rooms a new form of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Orthopedics
دوره 38 2 شماره
صفحات -
تاریخ انتشار 2015