Multiparameter flow cytometry of fluorescent protein reporters.

نویسندگان

  • Teresa S Hawley
  • Donald J Herbert
  • Shannon S Eaker
  • Robert G Hawley
چکیده

Reporters based on the green fluorescent protein (GFP) from the jellyfish Aequorea victoria and GFP-like proteins from other marine organisms provide valuable tools to monitor gene transfer and expression noninvasively in living cells. Stable cell lines were generated from the Sp2/0-Ag14 hybridoma that express up to three spectral enhanced versions of GFP, the enhanced cyan fluorescent protein (ECFP), the enhanced green fluorescent protein (EGFP), and the enhanced yellow fluorescent protein (EYFP), and/or a variant of the Discosoma coral red fluorescent protein (DsRed). The panel of lines was used to demonstrate a flow cytometric procedure for simultaneous analysis of all four fluorescent proteins that utilizes dual-laser excitation at 488 nm and 407 nm. Additional schemes for simultaneous detection of two, three or four of these fluorescent proteins are also presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Guide to red fluorescent proteins and biosensors for flow cytometry.

Since the discovery of the first red fluorescent protein (RFP), named DsRed, 12 years ago, a wide pallet of red-shifted fluorescent proteins has been cloned and biotechnologically developed into monomeric fluorescent probes for optical microscopy. Several new types of monomeric RFPs that change the emission wavelength either with time, called fluorescent timers, or after a brief irradiation wit...

متن کامل

Multiparameter flow cytometry quantification of bone marrow plasma cells at diagnosis provides more prognostic information than morphological assessment in myeloma patients.

Quantification of bone marrow plasma cells in multiple myeloma patients using conventional morphology is of limited prognostic value, while the merit of multiparameter flow cytometry immunophenotyping is still considered unproven. Here we compare the bone marrow plasma cell counts obtained by morphology and multiparameter flow cytometry and explore the potential prognostic impact of both techni...

متن کامل

A universal flow cytometry assay for screening carbohydrate-active enzymes using glycan microspheres.

We describe a simple, multiplexed assay that integrates glycan synthesis, bioconjugation to microspheres, fluorescent chemical/biochemical detection and multiparameter flow cytometric analysis to screen activities of different families of carbohydrate-active enzymes.

متن کامل

Single-cell analysis of siRNA-mediated gene silencing using multiparameter flow cytometry.

BACKGROUND Use of synthetic short interfering RNAs (siRNAs) to study gene function has been limited by an inability to selectively analyze subsets of cells in complex populations, low and variable transfection efficiencies, and semiquantitative assays for measuring protein down-regulation. Intracellular flow cytometry can overcome these limitations by analyzing populations at the single-cell le...

متن کامل

Fluorescent Reporter Signals, EGFP, and DsRed, Encoded in HIV-1 Facilitate the Detection of Productively Infected Cells and Cell-Associated Viral Replication Levels

Flow cytometric analysis is a reliable and convenient method for investigating molecules at the single cell level. Previously, recombinant human immunodeficiency virus type 1 (HIV-1) strains were constructed that express a fluorescent reporter, either enhanced green fluorescent protein, or DsRed, which allow the monitoring of HIV-1-infected cells by flow cytometry. The present study further inv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Methods in molecular biology

دوره 263  شماره 

صفحات  -

تاریخ انتشار 2004