Effect of air transport on acrylate/methacrylate allergens in syringes and IQ chambers.

نویسندگان

  • Anthony Teik-Jin Goon
  • Magnus Bruze
  • Erik Zimerson
  • Osten Sörensen
  • Marléne Isaksson
چکیده

Three methacrylate allergens, methyl methacrylate (MMA), 2-hydroxyethyl methacrylate (2-HEMA), and ethyleneglycol dimethacrylate (EGDMA), were purchased from Chemotechnique Diagnostics (Vellinge, Sweden). These were compounded in 2.0% wt/wt petrolatum (pet.) and inserted into capped polypropylene syringes (with and without aluminium foil wrapping) and IQ chambers (Chemotechnique Diagnostics) without aluminium foil. Approximately 4 ml of each preparation was inserted into a syringe and approximately 30 mg of preparation into each polyethylene IQ chamber. The tape with the chambers was protected by the manufacturer’s stiff plastic cover with 10 compartments that correspond to the chambers on the tape. The syringes were sent in triplicate for each allergen with and without aluminium foil wrapping, and two unwrapped samples in IQ chambers for each methacrylate were sent. These were then packaged in an airtight plastic bag and sent via normal airmail to the National Skin Centre, Singapore. Upon receipt of the packaging, the allergens were then sent back to the Malmö department immediately, without being opened in Singapore. The estimated travelling time was approximately 28 hr by air and at least 4 hr on land. Upon arrival back at our laboratory, the allergens in the syringes and IQ chambers were analysed by highperformance liquid chromatography (to be published) for actual methacrylate allergen content. The detection limit for the allergens in the system that we used was 0.00011%. The results are shown in Table 1. After allowing for the allergen loss due to our compounding process, we found that the patch test preparations sent in capped syringes retained their original allergen concentration whether or not they had been wrapped in aluminium foil, whereas those in IQ chambers with lids but without aluminium foil wrapping had lost almost their entire allergen content, for MMA and 2-HEMA in particular.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Erythema multiforme contact dermatitis after accidental exposure to acrylate-based printing inks.

Acrylates are well recognized as allergens. People working in the graphic arts field are exposed to acrylate-based printing inks and are therefore at high risk for occupational allergic contact dermatitis to acrylates. The most commonly used acrylic monomers in the printing process are 2-hydroxyethyl acrylate, 2-hydroxypropyl acrylate, 2hydroxypropyl methacrylate, 2-hydroxyethyl methacrylate, a...

متن کامل

Synthesis and Characterization of Fe3O4 Magnetic Nanoparticles Coated with Carboxymethyl Chitosan Grafted Sodium Methacrylate

N-sodium acrylate-O-carboxymethyl chitosan [CMCH-g-PAA(Na)] bound Fe3O4 nanoparticles were developed as a novel magnetic nanoparticles with an ionic structure that can be potentially used in many fields. CMCH-g-PAA (Na) was obtained by grafting of sodium polyacrylate on O-carboxymethyl chitosan, which is an amphiphilic polyelectrolyte with the biocompatibility and biodegra...

متن کامل

Effect of air column in transport canisters on measured gas contents of coal

Canister desorption is a widely used technique to measure the gas content of coal. The gas content data, when normalized to volume/weight and multiplied by coal seam mass, is used to estimate the gas in place in an area around the cored hole. However, the gas content and the percentage of each constituent are likely to be influenced by trapped air in the canister at the time of the coal enclosu...

متن کامل

Chemical modification of maleic anhydride polymers with carbazole

Maleic anhydride (MAN) copolymers with methyl methacrylate(MMA), ethyl methacrylate(EMA), methyl acrylate(MA), ethyl acrylate (EA) and buthyl acrylate (BA) ( in a 1:1 mole ratio) were synthesized by free radical polymerizations method under vacuum -azobis(isobutironitrile)(AIBN) as an initiator of reaction at 701C. The copolymer compositions were determined using related 1H NMR spectra techni...

متن کامل

[Sensitization to acrylates caused by artificial acrylic nails: review of 15 cases].

BACKGROUND Allergic contact dermatitis due to acrylates present in the workplace is a disease frequently reported among dentists, printers, and fiberglass workers. Recently, the number of cases of contact allergic dermatitis among beauticians specialized in sculpting artificial nails has increased. OBJECTIVE Our objective was to study the clinical characteristics and allergens implicated in a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Contact dermatitis

دوره 63 5  شماره 

صفحات  -

تاریخ انتشار 2010