Direct simulation Monte Carlo study of effects of thermal nonuniformities in electron-beam physical vapor deposition
نویسندگان
چکیده
Direct simulation Monte Carlo study of effects of thermal nonuniformities in electron-beam physical vapor deposition" (2011). In a typical electron-beam physical vapor deposition system, there is limited control over how the high-power electron beam heats the metal surface. This leads to thermal nonuniformities at the melt. Three-dimensional direct simulation Monte Carlo simulations were performed with the aim of quantifying the effect of such spatial variations of source temperature in thin film depositions using an electron-beam physical vapor deposition system. The source temperature distribution from a typical deposition process was used in the direct simulation Monte Carlo simulations performed for various mass flow rates. The use of an area-averaged temperature is insufficient for all mass flow rates due to the highly nonlinear relationship between temperature and saturation number density, and hence, the mass flux. The mass flow rate equivalent temperature was determined, and the simulations performed with this temperature were compared with those corresponding to the actual nonuniform temperature distribution. For low mass flow rates, the growth rates depend very weakly on the spatial variation of temperature as long as an equivalent temperature corresponding to the same mass flow rate was used. However, as the mass flow rate increases, the error associated with this approximation increases. For deposition processes with source Knudsen numbers less than 0.05, it is not possible to account for the spatial nonuniformities in temperature using the total mass flow rate without significant errors. For a given mass flow rate, the errors associated with using an equivalent temperature decrease with increasing collector plane distance since the flow is allowed to expand further, thereby decreasing the effects of slit temperature nonuniformities.
منابع مشابه
Direct simulation Monte Carlo modeling of e-beam metal deposition
Three-dimensional direct simulation Monte Carlo ͑DSMC͒ method is applied here to model the electron-beam physical vapor deposition of copper thin films. Various molecular models for copper-copper interactions have been considered and a suitable molecular model has been determined based on comparisons of dimensional mass fluxes obtained from simulations and previous experiments. The variable hard ...
متن کاملMolecular Models for DSMC Simulations of Metal Vapor Deposition
The direct simulation Monte Carlo (DSMC) method is applied here to model the electron-beam (e-beam) physical vapor deposition of copper thin films. A suitable molecular model for copper-copper interactions have been determined based on comparisons with experiments for a 2D slit source. The model for atomic copper vapor is then used in axi-symmetric DSMC simulations for analysis of a typical e-b...
متن کاملA MONTE CARLO MODEL FOR PREDICTING THE EROSION RATE OF EB PVD TBCs
Since the introduction of electron beam (EB) physical vapour deposition (PVD) thermal barrier coatings (TBCs) and their application to moving components in the hot gas stream, erosion has become a prime concern. EB PVD TBCs, due to their unique columnar microstructure are far more strain tolerant than their plasma sprayed (PS) counter parts and can thus be used under more exacting operating con...
متن کاملComparison of Electron-Beam Dose Distributions in a Heterogeneous Phantom Obtained Using Radiochromic Film Dosimetry and Monte Carlo Simulation
Introduction: Nowadays new radiochromic films have an essential role in radiotherapy dosimetry. Properties such as high sensitivity, good reproducibility, high spatial resolution, easy readout and portability have made them attractive for dosimetry, especially in high-dose-gradient regions. Material and Methods: In this study, electron-beam dose distributions in homogenous and heterogeneous pha...
متن کاملMonte Carlo Simulation of a Linear Accelerator and Electron Beam Parameters Used in Radiotherapy
Introduction: In recent decades, several Monte Carlo codes have been introduced for research and medical applications. These methods provide both accurate and detailed calculation of particle transport from linear accelerators. The main drawback of Monte Carlo techniques is the extremely long computing time that is required in order to obtain a dose distribution with good statistical accuracy. ...
متن کامل