Measurement of the axial length of cataract eyes by laser Doppler interferometry.

نویسندگان

  • C K Hitzenberger
  • W Drexler
  • C Dolezal
  • F Skorpik
  • M Juchem
  • A F Fercher
  • H D Gnad
چکیده

PURPOSE To examine the applicability of the recently developed laser Doppler interferometry technique for measuring the axial length of cataract eyes in a realistic clinical situation. To determine the performance of the instrument as a function of cataract grade. To compare the results to those of ultrasound methods. METHODS A total of 196 cataract eyes of 100 patients were examined. The axial eye length was determined by laser Doppler interferometry and by two different ultrasound techniques, the applanation technique and the immersion technique. The cataract grade was determined by a commercial instrument that measures backscattered light. RESULTS Laser Doppler interferometry worked very well except in the cases of the highest cataract grades (4% of the eyes of this study were not measurable because of a too-high lens density). Only 3.5% of the other eyes were not measurable because of fixation problems of the patients. The precision of laser Doppler interferometry is not influenced by the cataract grade (except the highest grade). The standard deviation of the geometric eye length is approximately 20 microns. Linear regression analysis revealed a very good correlation of laser Doppler interferometry and ultrasonic measurements, but a systematic difference was found. The eye lengths measured by laser Doppler interferometry were about 0.18 mm longer than those measured by the immersion technique and about 0.47 mm longer than those measured by the applanation technique. CONCLUSION These differences are attributed to the laser Doppler interferometry results including the retinal thickness and indentation of the cornea by the applanation technique. The main advantages of the laser Doppler interferometry technique are high precision, high accuracy, and more comfort for the patient because it is a noncontact method, anesthesia is unnecessary, and the risk of corneal infection is avoided.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Partial Coherence Laser Interferometry in Highly Myopic versus Emmetropic Eyes

PURPOSE To investigate the reliability of partial coherence laser interferometry for optical biometry in highly myopic eyes. METHODS Axial length measurements by the IOLMaster (Carl Zeiss Meditec, Germany) with signal-to-noise ratio (SNR) ≥2 were performed in 52 consecutive myopic subjects with axial length ≥26.5 mm and 45 emmetropic patients before cataract surgery. Axial length measurements...

متن کامل

Immersion A-scan compared with partial coherence interferometry: outcomes analysis.

PURPOSE To compare 2 methods of axial length measurement, immersion ultrasonography and partial coherence interferometry, and to elucidate surgical outcomes based on immersion measurements. SETTING Oregon Eye Institute, Eugene, Oregon, USA. METHODS Axial length measurements in 50 cataractous eyes were obtained by optical biometry (IOLMaster, Zeiss Humphrey Systems) and immersion ultrasound ...

متن کامل

Performance of conventional biometry vs. integrated laser interferometry with keratometry device in intraocular lens measurement.

OBJECTIVE To compare the performance of the Conventional Biometry (CB) (Applanation Ultrasound and Keratometry) and the Integrated Laser Interferometry with Keratometry Device (LI) in the measurement of Intraocular Lens (IOL). MATERIAL AND METHOD A prospective study of 100 eyes in 50 cataract patients was conducted. The IOL measurement using the LIfollowed by the CB was done on all eyes. The ...

متن کامل

Intracameral Interleukin 1β, 6, 8, 10, 12p, Tumor Necrosis Factor α and Vascular Endothelial Growth Factor and Axial Length in Patients with Cataract

OBJECTIVE To assess associations between the aqueous humour concentration of interleukin IL-1β, IL-6, IL-8, IL-10 and IL-12p, tumor necrosis factor α (TNF-α) and vascular endothelial growth factor (VEGF) and axial length in eyes with cataract. METHODS The hospital-based investigation included patients who underwent cataract surgery between March 2014 and April 2014. Using aqueous humour colle...

متن کامل

Axial Length Measurement in Asteroid Hyalosis: Comparing Laser Interferometry and Ultrasound A-scan

© 2009 by the Iranian Society of Ophthalmology Published by Otagh-e-Chap Inc. 29 Purpose: To compare laser interferometry (LI) and ultrasound A-scan in measurement of axial length (AL) in eyes with asteroid hyalosis Methods: Twenty three patients with unilateral moderate to severe asteroid hyalosis determined by B-scan ultrasonography images participated in the study. The AL measurements were o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 34 6  شماره 

صفحات  -

تاریخ انتشار 1993