Use of a pressure sensing sheath: comparison with standard means of blood pressure monitoring in catheterization procedures

نویسندگان

  • Phillip D Purdy
  • Charles South
  • Richard P Klucznik
  • Kenneth C Liu
  • Robin L Novakovic
  • Ajit S Puri
  • G Lee Pride
  • Beverly Aagaard-Kienitz
  • Abishek Ray
  • Alan C Elliott
چکیده

PURPOSE Monitoring of blood pressure (BP) during procedures is variable, depending on multiple factors. Common methods include sphygmomanometer (BP cuff), separate radial artery catheterization, and side port monitoring of an indwelling sheath. Each means of monitoring has disadvantages, including time consumption, added risk, and signal dampening due to multiple factors. We sought an alternative approach to monitoring during procedures in the catheterization laboratory. METHODS A new technology involving a 330 µm fiberoptic sensor embedded in the wall of a sheath structure was tested against both radial artery catheter and sphygmomanometer readings obtained simultaneous with readings recorded from the pressure sensing system (PSS). Correlations and Bland-Altman analysis were used to determine whether use of the PSS could substitute for these standard techniques. RESULTS The results indicated highly significant correlations in systolic, diastolic, and mean arterial pressures (MAP) when compared against radial artery catheterization (p<0.0001), and MAP means differed by <4%. Bland-Altman analysis of the data suggested that the sheath measurements can replace a separate radial artery catheter. While less striking, significant correlations were seen when PSS readings were compared against BP cuff readings. CONCLUSIONS The PSS has competitive functionality to that seen with a dedicated radial artery catheter for BP monitoring and is available immediately on sheath insertion without the added risk of radial catheterization. The sensor is structurally separated from the primary sheath lumen and readings are unaffected by device introduction through the primary lumen. Time delays and potential complications from radial artery catheterization are avoided.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه اندازه گیری فشارخون توسط گوشی معمولی با گوشی تلفیقی

Background and Purpose: Blood pressure (BP) is routinely evaluated intermittently during the clinical status for care and treatment. The most common method to measure BP is by using the sphygmomanometer with a stethoscope. This method may be difficult for medical students that will use BP for medical evaluation. The purpose of this study was to compare the accuracy of double stethoscope devic...

متن کامل

The role of stress on the rise of blood pressure

Background: The virtual rise of blood pressure resulted from stress, that is observed in subjects that are tested in medical centers, can be oftenly corrected by holter. This phenomenon causes such persons not to response to the common anti blood pressure treatments (2). Materials and methods: This descriptive study was conducted 2006-2007 at the heart clinic of Shohadaye–Ashayer hospital in Kh...

متن کامل

Comparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study

Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...

متن کامل

Comparison of Various Blood Pressure Measurement Techniques with Standard Office Based Blood Pressure Mesurement

Introduction: In order to control Hypertension, it is necessary to understand the methods of blood pressure measurement. Recent guidelines emphasize on employing appropriate blood pressure measurement techniques and white coat hypertension. Definition and methods of blood pressure measurement have changed in the American guideline based on SPRINT trial (Systolic Blood Pressure Intervention Tria...

متن کامل

Comparison of the Effects of Sodium metavanadate and Zinc Sulfate Supplementation on Lipid and Glu-cose in Patients with Type 2 Diabetes

Type 2 diabetes mellitus is a chronic illness causing considerable morbidity and mortality. Enormous advances have been made in medical care but more people are still having tendency to use herbal or alternative remedies. This study is a randomized, controlled trial on type 2 diabetic patients. The subject consisted of 60 patients divided randomly into three groups and supple-mented daily with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017