Sound Analysis in an In Vitro Endotracheal Tube Model

نویسندگان

  • Young Sik Park
  • Young Wook Kee
  • Kwang Suk Park
  • Jinwoo Lee
  • Sang-Min Lee
  • Jae-Joon Yim
  • Chul-Gyu Yoo
  • Young Whan Kim
  • Sung Koo Han
  • Seok-Chul Yang
چکیده

BACKGROUND/AIMS Complete endotracheal tube obstruction is a medical emergency, and partial occlusion causes increased breathing rates and failure to wean off mechanical ventilation. Partial occlusion may be underestimated due to the lack of proper detection methods. We tested whether the sound of an endotracheal tube could be used to detect an endotracheal tube obstruction using an in vitro model. METHODS An endotracheal tube was connected to a ventilator on one end and a test lung on the other. Sounds were recorded with a microphone located inside the endotracheal tube via a connector. During mechanical ventilation, we changed the endotracheal tube internal diameter from 5.0 to 8.0 mm and different grades of obstruction at different sites were used along the tube. Sound energy was compared among the different conditions. RESULTS The energy of endotracheal tube sounds was positively correlated with the internal diameter and negatively correlated with the degree of obstruction. The rate of decline in energy differed with obstruction location. When the obstruction was more distal, the rate of decline in endotracheal sound energy was more rapid. CONCLUSIONS Changes in the sound of an endotracheal tube can be used to detect an obstruction. Further studies are needed for clinical application.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In-line Acoustic System to Position and Monitor Infant-sized Endotracheal Tubes

Ensuring that the distal end of an endotracheal tube is properly located within the trachea, and that the tube is not obstructed by mucous deposition, is a major clinical concern. This concern is heightened in infant care, where the relatively small geometries predicate higher risks. A novel acoustic system was developed to allow for the continuous monitoring of endotracheal tube position and p...

متن کامل

New Metal Shield for the Endotracheal Tube during Laser Endolaryngeal Surgery

Introduction: To present and assess a newly designed autoclavable, reusable tube shield for an endotracheal tube (ETT) during laser laryngeal surgery.   Materials and Methods: This study included patients scheduled for endolaryngeal laser surgery. A carbonated stainless-steel hemisphere shield (~1.5×0.6 mm) connected to a silk thread passing through a hole in its middle near upper edge was ...

متن کامل

Effect of Stabilizing Endotracheal Tube on Quality of Airway Management in Patients Hospitalized in ICU

Background: The unplanned departure of endotracheal tube is one of the main complications for endotracheal intubation. In addition to endotracheal extubation, its movement can also lead to damage to the oral cavity. Stabilizing endotracheal tube is the most important factor that can prevent unplanned departure of endotracheal tube as well as its movement. The current study was done with the aim...

متن کامل

The Effect of Instructing the Principles of Endotracheal Tube Suctioning on Knowledge and Performance of Nursing Staff Working in Neonatal Intensive Care Units in Shiraz University of Medical Sciences

Introduction: Nurses must be aware of the risks regarding endotracheal tube suctioning and should have continuing education in this field. This study was performed to assess the impact of instruction on the knowledge and performance of NICU nursing staff in Shiraz University of Medical Sciences in 2006. Methods: Fifty nurses of neonatal intensive care units participated in this quasi experimen...

متن کامل

Effect of body position and head of bed angle on intra-abdominal and endotracheal tube cuff pressure in mechanically ventilated patients

Introduction: Changing position is one of the typical nursing care in intensive care units. This study aimed to investigate the effect of body positioning on intra-abdominal pressure and endotracheal tube cuff pressure and their relationship with each other in patients undergoing mechanical ventilation Materials and Methods: This was a before-after clinical trial study performed on 70 patients ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 26  شماره 

صفحات  -

تاریخ انتشار 2011