Reference dosimetry and small - field dosimetry in external beam radiotherapy : Results from a Danish intercomparison study
نویسندگان
چکیده
max. 2000 char.): A comparison of dosimetry methods at different clinics can be used as a means to uncover systematic uncertainties in radiotherapy. To assess the current status of reference dosimetry and small-field dosimetry in clinical practice, a collaborative comparison study involving several dosimetry methods was performed by DTU Nutech at six Danish clinics. The first part of the intercomparison regarded the consistency of reference dosimetry. Absorbed dose to water under reference conditions was measured using a Farmer ionization chamber, and was found to agree within 1 % with the daily dose checks obtained routinely at each clinic. The second part of the study concerned the accuracy of small-field dosimetry and dose calculations. The geometric size of small fields down to 1 cm x 1 cm was measured using radiochromic film. Minor discrepancies were seen between the nominal field sizes set by the collimators and the measured field sizes, although one clinic showed field dimensions that were down to 21 ± 3 % smaller than expected. Small-field correction factors were estimated for a PinPoint chamber and a diamond detector using a fibre-coupled organic scintillator as reference, after correcting for volume averaging. The corrections were found to be within 2 % down to the 1 cm x 1 cm field size. Output factor measurements performed with the three detectors were compared with the commissioning beam data originally acquired by the individual clinics using their own detectors and protocols, and with dose calculations performed using the treatment planning systems. Measured output factors agreed within 3 % with commissioning beam data and within 2 % with dose calculations for small MLC-defined fields. The study demonstrated (i) consistency of reference dosimetry and small-field dosimetry on a national level, and (ii) clinical applications of fiber-coupled plastic scintillators. The study also demonstrated that the estimation of detectorspecific correction factors in small fields is consistent among clinics and linac models, supporting the robustness and usefulness of the proposed IAEA formalism for detector-specific correction factors for non-reference fields. ISBN 978-87-995321-8-6 Group Reg. No.: DTU-Nutech-8(EN) Sponsorship: This work was supported by the Danish Cancer Society (R40-A1902) and CIRRO – Center for Interventional Research in Radiation Oncology, supported by the Lundbeck Foundation. The work was partly carried out within the EMRP: “Metrology for radiotherapy using complex radiation fields” (HLT09). The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union.
منابع مشابه
Some steps towards establishing a tertiary standard dosimetry laboratory at a radiotherapy department
Background: In order to deliver the precise dose to the target in radiotherapy, absorbed dose to water at the reference point should be assessed. When the calibration procedure is performed for a reference dosimeter in the 60Co beam of a Secondary Standard Dosimetry Laboratory (SSDL), the total uncertainty in absorbed dose to water (Dw) is estimated to be approximately 1.5%. This study attempts...
متن کاملA dosimetric intercomparison of kilovoltage X-rays, megavoltage photons and electrons in the Republic of Ireland.
BACKGROUND AND PURPOSE A comprehensive dosimetry intercomparison has been carried out involving all the radiotherapy centres, all external beam modalities and every radiotherapy treatment unit in the Republic of Ireland. MATERIALS AND METHODS Reference point measurements were made for all megavoltage photon beams. Doses were also investigated in planned three-field distributions. One of these...
متن کاملSmall photon field dosimetry using EBT2 Gafchromic film and Monte Carlo simulation
Background: Small photon fields are increasingly used in modern radiotherapy especially in intensity modulated radiation therapy (IMRT) and stereotactic radiosurgery (SRS) treatments. Accurate beam profile and central axis depth doses measurements of such beams are complicated due to the electron disequilibrium. Hence the EBT2 (external beam therapy) Gafchromic film was used for dosimetry of sm...
متن کاملSkin in vivo Dosimetry in Radiotherapy
Introduction: Due to the prevalence of skin problems in patients after radiotherapy, skin dose measuring is importance. Content: Skin in vivo dosimetry means measuring the patient's (or phantom) skin dose during radiotherapy. According to the ICRP 59, the dose at the depth of 0.07 mm is known as a skin dose. The most radiosensitive epidermis cells are located...
متن کاملCommissioning the First Mobile Dedicated Accelerator for Intraoperative Electron Radiotherapy in Iran
Introduction: Intraoperative radiotherapy is a radiotherapy technique in which a high single fraction of radiation dose is delivered to the patient after surgery and Concurrent with anesthesia time. The most frequent method for IORT implementation is Intraoperative electron radiotherapy (IOERT), in which, some dedicated and high dose per pulse electron accelerators are employe...
متن کامل