Malaria detection using inertial microfluidics.

نویسندگان

  • Majid Ebrahimi Warkiani
  • Andy Kah Ping Tay
  • Bee Luan Khoo
  • Xu Xiaofeng
  • Jongyoon Han
  • Chwee Teck Lim
چکیده

Diagnosis of malaria at the early stage of infection is challenging due to the difficulty in detecting low abundance parasites from blood. Molecular methods such as real-time polymerase chain reaction (qPCR) can be especially useful for detecting low parasitemia levels due to their high sensitivity and their ability to recognize different malarial species and strains. Unfortunately, the accuracy of qPCR-based malaria detection can be compromised by many factors, including the limited specificity of primers, presence of PCR inhibitors in blood serum and DNA contamination from nucleated blood cells. Here, we use a label-free, shear-modulated inertial microfluidic system to enrich malaria parasites from blood so as to facilitate a more reliable and specific PCR-based malaria detection. This technique capitalizes on cell focusing behaviors in high aspect ratio microchannels coupled with pinched flow dynamics to isolate ring-stage malaria parasites from lysed blood containing white blood cells (WBCs). In this high aspect ratio (ratio of the channel height to the width) platform, the high shear rate along the channel width causes the dispersed WBCs at the inlet to migrate and align into two streams near the channel sidewalls while the malaria parasites remain unfocused. Sensitive detection of parasites at spiked densities ranging from 10(3) to 10(4)Plasmodium falciparum parasites per mL (~2-10 per μL) has been demonstrated; they have also been quantified in whole blood using qPCR. This is approximately 100-fold more sensitive than the gold standard conventional microscopy analysis of thick blood smears. The simplicity of this device makes it ideal for integration with an automatic system for ultra-fast and accurate detection despite low levels of parasitemia. It can also help in malaria screening and elimination efforts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamics analysis of microparticles in inertial microfluidics for biomedical applications

Inertial microfluidics-based devices have recently attracted much interest and attention due to their simple structure, high throughput, fast processing and low cost. They have been utilised in a wide range of applications in microtechnology, especially for sorting and separating microparticles. This novel class of microfluidics-based devices works based on intrinsic forces, which cause micropa...

متن کامل

Direct detection and drug-resistance profiling of bacteremias using inertial microfluidics.

Detection of bacteria in bloodstream infections and their antibiotic susceptibility patterns is critical to guide therapeutic decision-making for optimal patient care. Current culture-based assays are too slow (>48 h), leading to excessive up-front use of broad-spectrum antibiotics and/or incorrect antibiotic choices due to resistant bacteria, each with deleterious consequences for patient care...

متن کامل

Rapid and High Sensitivity Malaria Diagnosis: a Microfluidics Approach

Most malaria deaths could be prevented if the infection is detected early. Thus, it is important to have access to a fast, sensitive, and reliable detection tool for the diagnosis of malaria in the clinical settings. However, the current malaria diagnosis relies on microscopic examination of blood smear, which is time consuming and labor intensive. Here, we present a novel malaria diagnosis tec...

متن کامل

Inertial Focusing of Microparticles in Curvilinear Microchannels

A passive, continuous and size-dependent focusing technique enabled by "inertial microfluidics", which takes advantage of hydrodynamic forces, is implemented in this study to focus microparticles. The objective is to analyse the decoupling effects of inertial forces and Dean drag forces on microparticles of different sizes in curvilinear microchannels with inner radius of 800 μm and curvature a...

متن کامل

Identification of malaria parasite-infected red blood cell surface aptamers by inertial microfluidic SELEX (I-SELEX)

Plasmodium falciparum malaria parasites invade and remodel human red blood cells (RBCs) by trafficking parasite-synthesized proteins to the RBC surface. While these proteins mediate interactions with host cells that contribute to disease pathogenesis, the infected RBC surface proteome remains poorly characterized. Here we use a novel strategy (I-SELEX) to discover high affinity aptamers that se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 15 4  شماره 

صفحات  -

تاریخ انتشار 2015